The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Mechanics Modeling of Tendon-Driven Continuum Manipulators
Abstract
Continuum robotic manipulators articulate due to their inherent compliance. Tendon actuation leads to compression of the manipulator, extension of the actuators, and is limited by the practical constraint that tendons cannot support compression. In light of these observations, we present a new linear model for transforming desired beam configuration to tendon displacements andviceversa. We begin from first principles in solid mechanics by analyzing the effects of geometrically nonlinear tendon loads. These loads act both distally at the termination point and proximally along the conduit contact interface. The resulting model simplifies to a linear system including only the bending and axial modes of the manipulator as well as the actuator compliance. The model is then manipulated to form a concise mapping from beam configuration-space parameters tonredundant tendon displacements via the internal loads and strains experienced by the system. We demonstrate the utility of this model by implementing an optimal feasible controller. The controller regulates axial strain to a constant value while guaranteeing positive tendon forces and minimizing their magnitudes over a range of articulations. The mechanics-based model from this study provides insight as well as performance gains for this increasingly ubiquitous class of manipulators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Khatib, O. (1987) · IEEE Journal on Robotics and Automation · doi:10.1109/jra.1987.1087068 · Cited by 2,940
Introduction to linear optimization
Bertsimas, D., & Tsitsiklis, J. N. (1997) · Cited by 2,705
Articulated Hands: Force Control and Kinematic Issues
Salisbury, J. K., & Craig, J. J. (1982) · The International Journal of Robotics Research · doi:10.1177/027836498200100102 · Cited by 1,544
Self-citationKinematics for multisection continuum robots
Jones, B. A., & Walker, I. D. (2006) · IEEE Transactions on Robotics · doi:10.1109/tro.2005.861458 · Cited by 955
Biologically inspired robots: snake-like locomotors and manipulators
(1994) · Choice Reviews Online · doi:10.5860/choice.32-0954 · Cited by 819
Continuum robots - a state of the art
Robinson, G., & Davies, J. B. C. (2003) · Proceedings 1999 IEEE International Conference on Robotics and Automation (Cat. No.99CH36288C) · doi:10.1109/robot.1999.774029 · Cited by 619
Robotic technology in surgery: Past, present, and future
Camarillo, D. B., Krummel, T. M., & Salisbury, J. K. (2004) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2004.08.025 · Cited by 535
Self-citationLarge deflection dynamics and control for planar continuum robots
Gravagne, I. A., Rahn, C. D., & Walker, I. D. (2003) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2003.812829 · Cited by 357
The da Vinci telerobotic surgical system: the virtual operative field and telepresence surgery
Ballantyne, G. H., & Moll, F. (2003) · Surgical Clinics of North America · doi:10.1016/s0039-6109(03)00164-6 · Cited by 338
Muller, A. (2005) · IEEE Transactions on Robotics · doi:10.1109/tro.2004.842341 · Cited by 196
Cited by
Design and Kinematic Modeling of Constant Curvature Continuum Robots: A Review
Webster, R. J., & Jones, B. A. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910368147 · Cited by 2,297
Shintake, J., Cacucciolo, V., Floreano, D., & Shea, H. (2018) · Advanced Materials · doi:10.1002/adma.201707035 · Cited by 1,938
Continuum Robots for Medical Applications: A Survey
Burgner-Kahrs, J., Rucker, D. C., & Choset, H. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2489500 · Cited by 1,557
Statics and Dynamics of Continuum Robots With General Tendon Routing and External Loading
Rucker, D. C., & Webster III, R. J. (2011) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2160469 · Cited by 669
Soft Manipulators and Grippers: A Review
Hughes, J., Culha, U., Giardina, F., Guenther, F., Rosendo, A., & Iida, F. (2016) · Frontiers in Robotics and AI · doi:10.3389/frobt.2016.00069 · Cited by 619
Dynamic Model of a Multibending Soft Robot Arm Driven by Cables
Renda, F., Giorelli, M., Calisti, M., Cianchetti, M., & Laschi, C. (2014) · IEEE Transactions on Robotics · doi:10.1109/tro.2014.2325992 · Cited by 482
Emerging Robotic Platforms for Minimally Invasive Surgery
Vitiello, V., Lee, S.-L., Cundy, T. P., & Yang, G.-Z. (2013) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2012.2236311 · Cited by 457
Shape Sensing Techniques for Continuum Robots in Minimally Invasive Surgery: A Survey
Shi, C., Luo, X., Qi, P., Li, T., Song, S., Najdovski, Z., Fukuda, T., & Ren, H. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2622361 · Cited by 420
Continuous Backbone “Continuum” Robot Manipulators
Walker, I. D. (2013) · ISRN Robotics · doi:10.5402/2013/726506 · Cited by 405
Soft Robots Modeling: A Structured Overview
Armanini, C., Boyer, F., Mathew, A. T., Duriez, C., & Renda, F. (2023) · IEEE Transactions on Robotics · doi:10.1109/tro.2022.3231360 · Cited by 336
Continuum Robots for Medical Interventions
Dupont, P. E., Simaan, N., Choset, H., & Rucker, C. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3141338 · Cited by 307
A Telerobotic System for Transnasal Surgery
Burgner, J., Rucker, D. C., Gilbert, H. B., Swaney, P. J., Russell, P. T., Weaver, K. D., & Webster, R. J. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2265804 · Cited by 294
Current and Emerging Robot-Assisted Endovascular Catheterization Technologies: A Review
Rafii-Tari, H., Payne, C. J., & Yang, G.-Z. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-013-0946-8 · Cited by 288
Stiffness Control of Surgical Continuum Manipulators
Mahvash, M., & Dupont, P. E. (2011) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2105410 · Cited by 265
Model-Less Feedback Control of Continuum Manipulators in Constrained Environments
Yip, M. C., & Camarillo, D. B. (2014) · IEEE Transactions on Robotics · doi:10.1109/tro.2014.2309194 · Cited by 262
Self-citationAlambeigi, F., Aghajani Pedram, S., Speyer, J. L., Rosen, J., Iordachita, I., Taylor, R. H., & Armand, M. (2020) · IEEE Transactions on Robotics · doi:10.1109/tro.2019.2946726 · Cited by 48
Metadata
- Authors
- Camarillo, D. B., Milne, C. F., Carlson, C. R., Zinn, M. R., & Salisbury, J. K.
- Venue
- IEEE Transactions on Robotics
- Published
- 2008-12
- Volume
- 24
- Issue
- 6
- Pages
- 1262-1273
- ISSN
- 1552-3098 (ISSN-L)
- 1941-0468
- OpenAlex
- W2147492425
- Cited by
- 655
- References
- 13
- FWCI
- 10.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.