CoChat

Modeling of Transmission Characteristics Across a Cable-Conduit System

Agrawal, Varun, Peine, William J., Yao, Bin · 2010 · IEEE Transactions on Robotics
Cited by 167

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Many robotic systems, like surgical robots, robotic hands, and exoskeleton robots, use cable passing through conduits to actuate remote instruments. Cable actuation simplifies the design and allows the actuator to be located at a convenient location, away from the end effector. However, nonlinear frictions between the cable and the conduit account for major losses in tension transmission across the cable, and a model is needed to characterize their effects in order to analyze and compensate for them. Although some models have been proposed in the literature, they are lumped parameter based and restricted to the very special case of a single cable with constant conduit curvature and constant pretension across the cable only. This paper proposes a mathematically rigorous distributed parameter model for cable-conduit actuation with any curvature and initial tension profile across the cable. The model, which is described by a set of partial differential equations in the continuous time-domain, is also discretized for the effective numerical simulation of the cable motion and tension transmission across the cable. Unlike the existing lumped-parameter-based models, the resultant discretized model enables one to accurately simulate the partial-moving/partial-sticking cable motion of the cable-conduit actuation with any curvature and initial tension profile. The model is further extended to cable-conduit actuation in pull-pull configuration using a pair of cables. Various simulations results are presented to reveal the unique phenomena like backlash, cable slacking, interaction between the two cables, and other nonlinear behaviors associated with the cable conduits in pull-pull configuration. These results are verified by experiments using two dc motors coupled with a cable-conduit pair. The experimental setup has been prepared to emulate a typical cable-actuated robotic system. Experimental results are compared with the simulations and various implications are discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tro.2010.2064014

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 167

Metadata

Authors
Agrawal, V., Peine, W. J., & Yao, B.
Venue
IEEE Transactions on Robotics
Published
2010-10
Volume
26
Issue
5
Pages
914-924
ISSN
  • 1552-3098 (ISSN-L)
  • 1941-0468
OpenAlex
W2154578892
Cited by
167
References
1
FWCI
4.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Modeling of Transmission Characteristics Across a Cable-Conduit System. https://app.cochat.ai/papers/10.1109/tro.2010.2064014
The paper
Agrawal, V., Peine, W. J., & Yao, B. (2010). Modeling of Transmission Characteristics Across a Cable-Conduit System. IEEE Transactions on Robotics. https://doi.org/10.1109/tro.2010.2064014

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.