The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Concentric Tube Robot Design and Optimization Based on Task and Anatomical Constraints
Open accessAbstract
Concentric tube robots are catheter-sized continuum robots that are well suited for minimally invasive surgery inside confined body cavities. These robots are constructed from sets of pre-curved superelastic tubes and are capable of assuming complex 3D curves. The family of 3D curves that the robot can assume depends on the number, curvatures, lengths and stiffnesses of the tubes in its tube set. The robot design problem involves solving for a tube set that will produce the family of curves necessary to perform a surgical procedure. At a minimum, these curves must enable the robot to smoothly extend into the body and to manipulate tools over the desired surgical workspace while respecting anatomical constraints. This paper introduces an optimization framework that utilizes procedureor patient-specific image-based anatomical models along with surgical workspace requirements to generate robot tube set designs. The algorithm searches for designs that minimize robot length and curvature and for which all paths required for the procedure consist of stable robot configurations. Two mechanics-based kinematic models are used. Initial designs are sought using a model assuming torsional rigidity. These designs are then refined using a torsionally-compliant model. The approach is illustrated with clinically relevant examples from neurosurgery and intracardiac surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simplex Method for Function Minimization
Nelder, J. A., & Mead, R. (1965) · The Computer Journal · doi:10.1093/comjnl/7.4.308 · Cited by 28,905
Real-Time Obstacle Avoidance for Manipulators and Mobile Robots
Khatib, O. (1986) · The International Journal of Robotics Research · doi:10.1177/027836498600500106 · Cited by 7,894
Cited by
Continuum Robots for Medical Applications: A Survey
Burgner-Kahrs, J., Rucker, D. C., & Choset, H. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2489500 · Cited by 1,557
Continuum Robots for Medical Interventions
Dupont, P. E., Simaan, N., Choset, H., & Rucker, C. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3141338 · Cited by 307
Self-citationRusso, M., Sadati, S. M. H., Dong, X., Mohammad, A., Walker, I. D., Bergeles, C., Xu, K., & Axinte, D. A. (2023) · Advanced Intelligent Systems · doi:10.1002/aisy.202200367 · Cited by 263
Self-citation
Metadata
- Authors
- Bergeles, C., Gosline, A. H., Vasilyev, N. V., Codd, P. J., del Nido, P. J., & Dupont, P. E.
- Venue
- IEEE Transactions on Robotics
- Published
- 2015-02
- Volume
- 31
- Issue
- 1
- Pages
- 67-84
- ISSN
- 1552-3098 (ISSN-L)
- 1941-0468
- OpenAlex
- W2063706473
- Cited by
- 178
- References
- 2
- FWCI
- 10.07
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.