The DOI matches its Crossref record.
Continuum Robot Stiffness Under External Loads and Prescribed Tendon Displacements
Abstract
Soft and continuum robots driven by tendons or cables have wide-ranging applications, and many mechanics-based models for their behavior have been proposed. In this paper, we address the unsolved problem of predicting robot deflection and stiffness with respect to environmental loads where the axial displacements of the tendon ends are held constant. We first solve this problem analytically for a tendon-embedded Euler-Bernoulli beam. Nondimensionalized equations and plots describe how tendon stretch and routing path affect the robot's output stiffness at any point. These analytical results enable stiffness analysis of candidate robot designs without extensive computational simulations. Insights gained through this analysis include the ability to increase robot stiffness by using converging tendon paths. Generalizing to large deflections in three dimensions (3-D), we extend a previous nonlinear Cosserat-rod-based model for tendon-driven robots to handle prescribed tendon displacements, tendon stretch, pretension, and slack. We then provide additional dimensionless plots in the actuated case for loads in 3-D. The analytical formulas and numerically computed model are experimentally validated on a prototype robot with good agreement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Real-time dynamics of soft and continuum robots based on Cosserat rod models
Till, J., Aloi, V., & Rucker, C. (2019) · The International Journal of Robotics Research · doi:10.1177/0278364919842269 · Cited by 419
Self-citationContinuum Robots for Medical Interventions
Dupont, P. E., Simaan, N., Choset, H., & Rucker, C. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3141338 · Cited by 307
Self-citationChallenges of continuum robots in clinical context: a review
da Veiga, T., Chandler, J. H., Lloyd, P., Pittiglio, G., Wilkinson, N. J., Hoshiar, A. K., Harris, R. A., & Valdastri, P. (2020) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ab9f41 · Cited by 280
Russo, M., Sadati, S. M. H., Dong, X., Mohammad, A., Walker, I. D., Bergeles, C., Xu, K., & Axinte, D. A. (2023) · Advanced Intelligent Systems · doi:10.1002/aisy.202200367 · Cited by 263
Robotics in the Construction Sector: Trends, Advances, and Challenges
Liu, Y., A.H., A., Haron, N. A., N.A., B., & Wang, H. (2024) · Journal of Intelligent & Robotic Systems · doi:10.1007/s10846-024-02104-4 · Cited by 60
Metadata
- Authors
- Oliver-Butler, K., Till, J., & Rucker, C.
- Venue
- IEEE Transactions on Robotics
- Published
- 2019-04
- Volume
- 35
- Issue
- 2
- Pages
- 403-419
- ISSN
- 1552-3098 (ISSN-L)
- 1941-0468
- OpenAlex
- W2909729638
- Cited by
- 193
- References
- 0
- FWCI
- 6.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuum Robot Stiffness Under External Loads and Prescribed Tendon Displacements. https://app.cochat.ai/papers/10.1109/tro.2018.2885923
- The paper
- Oliver-Butler, K., Till, J., & Rucker, C. (2019). Continuum Robot Stiffness Under External Loads and Prescribed Tendon Displacements. IEEE Transactions on Robotics. https://doi.org/10.1109/tro.2018.2885923
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.