Securing Insulin Pump System Using Deep Learning and Gesture Recognition
Abstract
Modern medical devices are equipped with radio communication chips enabling medical practitioners to remotely and continuously monitor patient's health. The conjunction of these medical devices with the radio communication chips and their internet connectivity exposes them to security and privacy risks. The insulin pump system is an autonomous, wearable external device, commonly used by diabetic patients to take insulin efficiently, as compared to manual injection through a syringe. Security attacks may disrupt the working of insulin pump system by delivering the lethal dose to patients and endanger their lives. In this paper, we ensure the correct dosing process of insulin pump system based on the combination of deep learning model and gestures performed by the patient. Specifically, we used Long Short-Term Memory (LSTM) recurrent neural network to predict the thresh hold value of insulin based on last three months log of insulin pump system. If the amount of insulin to be injected by the insulin pump system is greater than our predicted thresh hold amount, then our system asks the patient to perform the gesture. After successful recognition of the patient's gesture, our solution compares the suspicious value of insulin with patient's gesture and identifies an attack.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Malicious events that compromise privacy of PII could include tampering with the connection between smart devices in the home or access to private information via wearable health monitoring devices.
“Malicious events that compromise the privacy of PII could include tampering with the connection between smart devices in the home or access to private information via wearable health monitoring devices [20], [21].”
From Federated Learning for Privacy Preservation in Smart Healthcare Systems: A Comprehensive Survey (2023) · cites this paper as [20]
Cites
Hochreiter, S., & Schmidhuber, J. (1997) · Neural Computation · doi:10.1162/neco.1997.9.8.1735 · Cited by 102,318 · see citing works
Deep learning for healthcare: review, opportunities and challenges
Miotto, R., Wang, F., Wang, S., Jiang, X., & Dudley, J. T. (2018) · Briefings in Bioinformatics · doi:10.1093/bib/bbx044 · Cited by 3,076 · see citing works
Vision based hand gesture recognition for human computer interaction: a survey
Rautaray, S. S., & Agrawal, A. (2012) · Artificial Intelligence Review · doi:10.1007/s10462-012-9356-9 · Cited by 1,535 · see citing works
Learning to Diagnose with LSTM Recurrent Neural Networks
Lipton, Z. C., Kale, D. C., Elkan, C., & Wetzel, R. (2015) · arXiv · doi:10.48550/arxiv.1511.03677 · Cited by 879 · see citing works
Risk Prediction with Electronic Health Records: A Deep Learning Approach
Cheng, Y., Wang, F., Zhang, P., & Hu, J. (2016) · SIAM International Conference on Data Mining · doi:10.1137/1.9781611974348.49 · Cited by 403 · see citing works
Survey on 3D Hand Gesture Recognition
Cheng, H., Yang, L., & Liu, Z. (2015) · IEEE Transactions on Circuits and Systems for Video Technology · doi:10.1109/tcsvt.2015.2469551 · Cited by 346 · see citing works
Hijacking an insulin pump: Security attacks and defenses for a diabetes therapy system
Li, C., Raghunathan, A., & Jha, N. K. (2011) · IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) · doi:10.1109/health.2011.6026732 · Cited by 328 · see citing works
SoK: Security and Privacy in Implantable Medical Devices and Body Area Networks
Rushanan, M., Rubin, A. D., Kune, D. F., & Swanson, C. M. (2014) · IEEE Symposium on Security and Privacy (S&P) · doi:10.1109/sp.2014.40 · Cited by 253 · see citing works
MedMon: Securing Medical Devices Through Wireless Monitoring and Anomaly Detection
Zhang, M., Raghunathan, A., & Jha, N. K. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2245664 · Cited by 185 · see citing works
Multi-task Prediction of Disease Onsets from Longitudinal Laboratory Tests
Razavian, N., Marcus, J., & Sontag, D. A. (2016) · Cited by 107 · see citing works
PIPAC: Patient infusion pattern based access control scheme for wireless insulin pump system
Hei, X., Du, X., Lin, S., & Lee, I. (2013) · IEEE Conference on Computer Communications (INFOCOM) · doi:10.1109/infcom.2013.6567115 · Cited by 83 · see citing works
Balancing security and utility in medical devices?
Rostami, M., Burleson, W. P., Koushanfar, F., & Juels, A. (2013) · ACM/IEEE Design Automation Conference (DAC) · doi:10.1145/2463209.2488750 · Cited by 77 · see citing works
Encryption for Implantable Medical Devices Using Modified One-Time Pads
Zheng, G., Fang, G., Shankaran, R., & Orgun, M. A. (2015) · IEEE Access · doi:10.1109/access.2015.2445336 · Cited by 61 · see citing works
On the Feasibility of Cryptography for a Wireless Insulin Pump System
Marin, E., Singelée, D., Yang, B., et al. (2016) · ACM Conference on Data and Application Security and Privacy (CODASPY) · doi:10.1145/2857705.2857746 · Cited by 42 · see citing works
Multi-task Prediction of Disease Onsets from Longitudinal Lab TestsPreprint
Razavian, N., Marcus, J., & Sontag, D. A. (2016) · arXiv (Cornell University) · doi:10.48550/arxiv.1608.00647 · Cited by 40 · see citing works
Machine-Learning Classifiers for Security in Connected Medical Devices
Gao, S., & Thamilarasu, G. (2017) · International Conference on Computer Communication and Networks (ICCCN) · doi:10.1109/icccn.2017.8038507 · Cited by 29 · see citing works
A Comparative Review on the Wireless Implantable Medical Devices Privacy and Security
Ankaralı, Z. E., Abbasi, Q. H., Demir, A. F., Serpedin, E., Qaraqe, K. A., & Arslan, H. (2014) · Wireless Mobile Communication and Healthcare · doi:10.4108/icst.mobihealth.2014.257411 · Cited by 25 · see citing works
A non-key based security scheme supporting emergency treatment of wireless implants
Zheng, G., Fang, G., Orgun, M. A., & Shankaran, R. (2014) · International Conference on Communications · doi:10.1109/icc.2014.6883392 · Cited by 21 · see citing works
A comparative review on the wireless implantable medical devices privacy and security
Ankaralı, Z. E., Abbasi, Q. H., Demir, A. F., Serpedin, E., Qaraqe, K. A., & Arslan, H. (2014) · International Conference on Wireless Mobile Communication and Healthcare · doi:10.1109/mobihealth.2014.7015957 · Cited by 21 · see citing works
Leal, Y., Abril, L. G., Lorencio, C., Bondía, J., & Vehı́, J. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2244092 · Cited by 17 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Federated Learning for Privacy Preservation in Smart Healthcare Systems: A Comprehensive Survey
Ali, M., Naeem, F., Tariq, M., & Kaddoum, G. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3181823 · Cited by 366 · see citing works
- Authors
- Ahmad, U., Song, H., Bilal, A., Saleem, S., & Ullah, A.
- Affiliations
- Beijing Institute of Technology (CN)
- National University of Sciences and Technology (PK)
- Venue
- 2018 17th IEEE International Conference On Trust, Security And Privacy In Computing And Communications/ 12th IEEE International Conference On Big Data Science And Engineering (TrustCom/BigDataSE)
- Publisher
- IEEE
- Published
- 2018-08
- Pages
- 1716-1719
- OpenAlex
- W2890662212
- Cited by
- 23
- References
- 20
- Citations by year
- 2025: 2 · 2024: 4 · 2023: 3 · 2022: 7 · 2021: 2 · 2020: 3 · 2019: 2
- FWCI
- 0.71
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE International Conference on Trust, Security and Privacy in Computing and Communications (TrustCom) (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Artificial Intelligence › Adversarial Robustness in Machine Learning
- Physical Sciences › Computer Science › Information Systems › Information and Cyber Security
- Physical Sciences › Computer Science › Information Systems › User Authentication and Security Systems
- Keywords
- medical device security, gesture recognition, deep learning, LSTM, attack detection, diabetes mellitus, wearable medical devices, remote patient monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review