The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Supplementary Load Frequency Control by Use of a Number of Both Electric Vehicles and Heat Pump Water Heaters
Abstract
A large integration of renewable energy sources such as wind power generation and photovoltaic generation causes some problems in power systems, e.g., distribution voltage rise and frequency fluctuation. Battery energy storage system (BESS) is one of the effective solutions to these problems. Due to a high cost of the BESS, an application of controllable loads such as electric vehicle (EV) and heat pump water heater (HPWH) to the power system control is considered in this paper for reduction of the required capacity of the BESS. This paper proposes a new supplementary load frequency control (LFC) method by use of a number of both the EVs and the HPWHs as controllable loads. The effectiveness of the proposed LFC method is shown by numerical simulations conducted on the power system model with a large integration of wind power generation and photovoltaic generation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peterson, S. B., Apt, J., & Whitacre, J. F. (2010) · Journal of Power Sources · doi:10.1016/j.jpowsour.2009.10.010 · Cited by 799
The economics of using plug-in hybrid electric vehicle battery packs for grid storage
Peterson, S. B., Whitacre, J. F., & Apt, J. (2010) · Journal of Power Sources · doi:10.1016/j.jpowsour.2009.09.070 · Cited by 500
Integration of Vehicle-to-Grid in the Western Danish Power System
Pillai, J. R., & Bak-Jensen, B. (2010) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2010.2072938 · Cited by 388
Provision of Load Frequency Control by PHEVs, Controllable Loads, and a Cogeneration Unit
Galus, M. D., Koch, S., & Andersson, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2107715 · Cited by 335
Shimizu, K., Masuta, T., Ota, Y., & Yokoyama, A. (2010) · International Conference on Power System Technology (POWERCON) · doi:10.1109/powercon.2010.5666064 · Cited by 141
Self-citationAutomatic Generation Control operation with electric vehicles
Almeida, P. M. R., Lopes, J. P., Soares, F. J., & de Vasconcelos, M. H. O. P. (2010) · IREP Symposium on Bulk Power System Dynamics and Control (IREP) · doi:10.1109/irep.2010.5563295 · Cited by 27
Cited by
Pandey, S. K., Mohanty, S. R., & Kishor, N. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.04.029 · Cited by 561
Decentralized Vehicle-to-Grid Control for Primary Frequency Regulation Considering Charging Demands
Liu, H., Hu, Z., Song, Y., & Lin, J. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2252029 · Cited by 482
Sizing of an Energy Storage System for Grid Inertial Response and Primary Frequency Reserve
Knap, V., Chaudhary, S. K., Stroe, D.-I., Swierczynski, M., Craciun, B.-I., & Teodorescu, R. (2016) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2015.2503565 · Cited by 424
Alhelou, H. H., Hamedani-Golshan, M.-E., Zamani, R., Heydarian-Forushani, E., & Siano, P. (2018) · Energies · doi:10.3390/en11102497 · Cited by 349
Vehicle-to-Grid Control for Supplementary Frequency Regulation Considering Charging Demands
Liu, H., Hu, Z., Song, Y., Wang, J., & Xie, X. (2015) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2382979 · Cited by 292
Metadata
- Authors
- Masuta, T., & Yokoyama, A.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2012-09
- Volume
- 3
- Issue
- 3
- Pages
- 1253-1262
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W1976837259
- Cited by
- 322
- References
- 6
- Type
- supplementary materials
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Supplementary Load Frequency Control by Use of a Number of Both Electric Vehicles and Heat Pump Water Heaters. https://app.cochat.ai/papers/10.1109/tsg.2012.2194746
- The paper
- Masuta, T., & Yokoyama, A. (2012). Supplementary Load Frequency Control by Use of a Number of Both Electric Vehicles and Heat Pump Water Heaters. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2012.2194746
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.