Electric Springs—A New Smart Grid Technology
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The scientific principle of “mechanical springs” was described by the British physicist Robert Hooke in the 1660's. Since then, there has not been any further development of the Hooke's law in the electric regime. In this paper, this technological gap is filled by the development of “electric springs.” The scientific principle, the operating modes, the limitations, and the practical realization of the electric springs are reported. It is discovered that such novel concept has huge potential in stabilizing future power systems with substantial penetration of intermittent renewable energy sources. This concept has been successfully demonstrated in a practical power system setup fed by an ac power source with a fluctuating wind energy source. The electric spring is found to be effective in regulating the mains voltage despite the fluctuation caused by the intermittent nature of wind power. Electric appliances with the electric springs embedded can be turned into a new generation of smart loads, which have their power demand following the power generation profile. It is envisaged that electric springs, when distributed over the power grid, will offer a new form of power system stability solution that is independent of information and communication technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grainger, J. J., & Stevenson, W. D. (1994) · CERN Document Server (European Organization for Nuclear Research) · Cited by 747
Reactive Power Compensation Technologies: State-of-the-Art Review
Dixon, J., Moran, L., Rodríguez, J., & Domke, R. (2005) · Proceedings of the IEEE · doi:10.1109/jproc.2005.859937 · Cited by 572
LINEARIZED THEORY OF ELASTICITY
(2017) · Advanced Series in Engineering Science · doi:10.1142/9789814713665_0007 · Cited by 224
Chung, H. S.-H., Ho, N.-M., Yan, W. M., Tam, P. W., & Hui, S. Y. R. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.907037 · Cited by 75
Self-citationTyll, H., & Schettle, F. (2009) · IEEE PES Power Systems Conference and Exposition · doi:10.1109/psce.2009.4840208 · Cited by 70
Cited by
Electric vehicle charging station placement: Formulation, complexity, and solutions
Lam, A. Y. S., Leung, Y.-W., & Chu, X. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2344684 · Cited by 436
Smart grids with intelligent periphery: An architecture for the energy internet
Wu, F. F., Varaiya, P. P., & Hui, R. S. Y. (2015) · Engineering · doi:10.15302/j-eng-2015111 · Cited by 94
Self-citation
Metadata
- Authors
- Hui, S. Y., Lee, C. K., & Wu, F. F.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2012-09
- Volume
- 3
- Issue
- 3
- Pages
- 1552-1561
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2012192910
- Cited by
- 460
- References
- 5
- FWCI
- 21.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electric Springs—A New Smart Grid Technology. https://app.cochat.ai/papers/10.1109/tsg.2012.2200701
- The paper
- Hui, S. Y., Lee, C. K., & Wu, F. F. (2012). Electric Springs—A New Smart Grid Technology. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2012.2200701
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.