The DOI matches its Crossref record.
Reliability-Constrained Optimal Sizing of Energy Storage System in a Microgrid
Abstract
This paper presents a model for calculating the optimal size of an energy storage system (ESS) in a microgrid considering reliability criterion. A larger ESS requires higher investment costs while reduces the microgrid operating cost. The optimal ESS sizing problem is proposed which minimizes the investment cost of the ESS, as well as expected microgrid operating cost. Utilizing the ESS, generation shortage due to outage of conventional units and intermittency of renewable units is handled; hence microgrid reliability criterion is satisfied. A practical model for ESS is utilized. Mixed-integer programming (MIP) is utilized to formulate the problem. Illustrative examples show the efficiency of the proposed model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Comprehensive Battery Energy Storage Optimal Sizing Model for Microgrid Applications
Alsaidan, I., Khodaei, A., & Gao, W. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2769639 · Cited by 312
Self-citationPlug-In Electric Vehicle to Home (V2H) Operation Under a Grid Outage
Shin, H., & Baldick, R. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2603502 · Cited by 175
Metadata
- Authors
- Bahramirad, S., Reder, W., & Khodaei, A.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2012-12
- Volume
- 3
- Issue
- 4
- Pages
- 2056-2062
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2004170288
- Cited by
- 529
- References
- 0
- FWCI
- 25.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliability-Constrained Optimal Sizing of Energy Storage System in a Microgrid. https://app.cochat.ai/papers/10.1109/tsg.2012.2217991
- The paper
- Bahramirad, S., Reder, W., & Khodaei, A. (2012). Reliability-Constrained Optimal Sizing of Energy Storage System in a Microgrid. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2012.2217991
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.