Robust LFC in a Smart Grid With Wind Power Penetration by Coordinated V2G Control and Frequency Controller

Vachirasricirikul, Sitthidet, Ngamroo, Issarachai·2014·IEEE Transactions on Smart Grid

Abstract

In the smart grid, the large scale wind power penetration tends to expand vastly. Nevertheless, due to the intermittent power generation from wind, this may cause a problem of large frequency fluctuation when the load-frequency control (LFC) capacity is not enough to compensate the unbalance of generation and load demand. Also, in the future transport sector, the plug-in hybrid electric vehicle (PHEV) is widely expected for driving in the customer side. Generally, the power of PHEV is charged by plugging into the home outlets as the dispersed battery energy storages. Therefore, the vehicle-to-grid (V2G) power control can be applied to compensate for the inadequate LFC capacity. This paper focuses on the new coordinated V2G control and conventional frequency controller for robust LFC in the smart grid with large wind farms. The battery state-of-charge (SOC) is controlled by the optimized SOC deviation control. The structure of frequency controller is a proportional integral (PI) with a single input. To enhance the robust performance and robust stability against the system uncertainties, the PI controller parameters and the SOC deviation are optimized simultaneously by the particle swarm optimization based on the fixed structure mixed H2/H∞ control. Simulation results show the superior robustness and control effect of the proposed coordinated controllers over the compared controllers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tsg.2013.2264921

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 254

Metadata

Authors
Vachirasricirikul, S., & Ngamroo, I.
Venue
IEEE Transactions on Smart Grid
Published
2014-01
Volume
5
Issue
1
Pages
371-380
ISSN
  • 1949-3053 (ISSN-L)
  • 1949-3061
OpenAlex
W2170100686
Cited by
254
References
1
FWCI
13.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Robust LFC in a Smart Grid With Wind Power Penetration by Coordinated V2G Control and Frequency Controller. https://app.cochat.ai/papers/10.1109/tsg.2013.2264921
The paper
Vachirasricirikul, S., & Ngamroo, I. (2014). Robust LFC in a Smart Grid With Wind Power Penetration by Coordinated V2G Control and Frequency Controller. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2013.2264921

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.