Robust LFC in a Smart Grid With Wind Power Penetration by Coordinated V2G Control and Frequency Controller
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
In the smart grid, the large scale wind power penetration tends to expand vastly. Nevertheless, due to the intermittent power generation from wind, this may cause a problem of large frequency fluctuation when the load-frequency control (LFC) capacity is not enough to compensate the unbalance of generation and load demand. Also, in the future transport sector, the plug-in hybrid electric vehicle (PHEV) is widely expected for driving in the customer side. Generally, the power of PHEV is charged by plugging into the home outlets as the dispersed battery energy storages. Therefore, the vehicle-to-grid (V2G) power control can be applied to compensate for the inadequate LFC capacity. This paper focuses on the new coordinated V2G control and conventional frequency controller for robust LFC in the smart grid with large wind farms. The battery state-of-charge (SOC) is controlled by the optimized SOC deviation control. The structure of frequency controller is a proportional integral (PI) with a single input. To enhance the robust performance and robust stability against the system uncertainties, the PI controller parameters and the SOC deviation are optimized simultaneously by the particle swarm optimization based on the fixed structure mixed H2/H∞ control. Simulation results show the superior robustness and control effect of the proposed coordinated controllers over the compared controllers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kennedy, J., & Eberhart, R. (2002) · Proceedings of ICNN'95 - International Conference on Neural Networks · doi:10.1109/icnn.1995.488968 · Cited by 58,192
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Power system dynamics : stability and control
Machowski, J., Bialek, J. W., & Bumby, J. R. (2008) · Durham Research Online (Durham University) · Cited by 2,348
Coordinated Charging of Plug-In Hybrid Electric Vehicles to Minimize Distribution System Losses
Sortomme, E., Hindi, M. M., MacPherson, S. D. J., & Venkata, S. S. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2010.2090913 · Cited by 1,155
A reliability perspective of the smart grid
Moslehi, K., & Kumar, R. (2010) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2010.2046346 · Cited by 932
Mixed H/sub 2//H/sub infinity / control: a convex optimization approach
Khargonekar, P. P., & Rotea, M. A. (1991) · IEEE Transactions on Automatic Control · doi:10.1109/9.85062 · Cited by 824
An Optimized EV Charging Model Considering TOU Price and SOC Curve
Cao, Y., Tang, S., Li, C., Zhang, P., Tan, Y., Zhang, Z., & Li, J. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2159630 · Cited by 719
Autonomous Distributed V2G (Vehicle-to-Grid) Satisfying Scheduled Charging
Ota, Y., Taniguchi, H., Nakajima, T., Liyanage, K. M., Baba, J., & Yokoyama, A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2167993 · Cited by 488
A Distributed Demand Response Algorithm and Its Application to PHEV Charging in Smart Grids
Fan, Z. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2185075 · Cited by 396
Hourly Coordination of Electric Vehicle Operation and Volatile Wind Power Generation in SCUC
Khodayar, M. E., Wu, L., & Shahidehpour, M. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2186642 · Cited by 392
Cited by
A survey on security control and attack detection for industrial cyber-physical systems
Ding, D., Han, Q.-L., Xiang, Y., Ge, X., & Zhang, X.-M. (2018) · Neurocomputing · doi:10.1016/j.neucom.2017.10.009 · Cited by 944
Yan, Z., & Xu, Y. (2020) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.2999890 · Cited by 398
Alhelou, H. H., Hamedani-Golshan, M.-E., Zamani, R., Heydarian-Forushani, E., & Siano, P. (2018) · Energies · doi:10.3390/en11102497 · Cited by 349
“LFC models considering the contribution of electric vehicles (EVs) are presented in [141].”
BackgroundRobust Frequency Control in an Islanded Microgrid: H∞ and μ-Synthesis Approaches
Bevrani, H., Feizi, M. R., & Ataee, S. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2446984 · Cited by 317
Fractional order PID controller for load frequency control
Sondhi, S., & Hote, Y. V. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2014.05.091 · Cited by 281
Kerdphol, T., Watanabe, M., Hongesombut, K., & Mitani, Y. (2019) · IEEE Access · doi:10.1109/access.2019.2920886 · Cited by 237
“The 15MW is used as the system base [31].”
MethodPham, T. N., Trinh, H., & Hien, L. V. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2449877 · Cited by 211
“The fleet of EVs is modeled [17]–[20] by a first-order with time constant Tei and gain Kei.”
MethodLoad Frequency Control of an Isolated Micro Grid Using Fuzzy Adaptive Model Predictive Control
Kayalvizhi, S., & Vinod Kumar, D. M. (2017) · IEEE Access · doi:10.1109/access.2017.2735545 · Cited by 175
“In [7] and [8], meta heuristic optimisation algorithms such as combined Particle Swarm Optimisation (PSO) with fuzzy logic and PSO based mixed H2/H∞ are proposed to enhance the frequency control in microgrid.”
MethodHaes Alhelou, H., Hamedani Golshan, M. E., & Askari-Marnani, J. (2018) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2018.02.013 · Cited by 175
Metadata
- Authors
- Vachirasricirikul, S., & Ngamroo, I.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2014-01
- Volume
- 5
- Issue
- 1
- Pages
- 371-380
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2170100686
- Cited by
- 254
- References
- 18
- FWCI
- 13.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.