A Decentralized Storage Strategy for Residential Feeders With Photovoltaics
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
This paper proposes a decentralized storage strategy to support voltage control in low-voltage (LV) residential feeders with high photovoltaic (PV) capacity installed. The proposed strategy is capable of preventing overvoltage situations during high PV generation periods, by the use of locally controlled battery energy storage systems (ESS) at the PV system grid interface. The traditional way of operating a domestic ESS is based on charging the battery as soon as the PV generation exceeds the consumption, without taking into account overvoltage events during high PV generation hours; the proposed storage concept improves the traditional approach, thanks to the provision of voltage support. A novel method, based on voltage sensitivity analysis, identifies a common power threshold that triggers the ESSs activation in the feeder. A Belgian residential LV feeder is used as a case study. Time-series simulations based on 1-year load and generation profiles verify the method findings and quantify the ESS size in terms of storage power and energy level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Understanding power quality problems: voltage sags and interruptions
(2000) · Choice Reviews Online · doi:10.5860/choice.37-4522 · Cited by 1,791 · cited 1×
“Meanwhile, the LV grid operation encounters more and more uncertainties with regard to voltage quality [1], [2].”
BackgroundSizing of Energy Storage for Microgrids
Chen, S. X., Gooi, H. B., & Wang, M. Q. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2160745 · Cited by 916 · cited 1×
“is the energy stored in the battery at time ; is the duration time of each interval [17].”
BackgroundIrradiance Forecasting for the Power Prediction of Grid-Connected Photovoltaic Systems
Lorenz, E., Hurka, J., Heinemann, D., & Beyer, H. G. (2009) · IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing · doi:10.1109/jstars.2009.2020300 · Cited by 721 · cited 1×
“1, can be optimized using day-ahead solar irradiation forecasts [11]; however, these are not used in this paper.”
MethodAssessment of Energy Distribution Losses for Increasing Penetration of Distributed Generation
MendezQuezada, V. H., RivierAbbad, J., & GomezSanRoman, T. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.873115 · Cited by 616 · cited 1×
“The definition of PV penetration used in this paper refers to the one given in [21]:”
MethodLiu, X., Aichhorn, A., Liu, L., & Li, H. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2177501 · Cited by 486 · cited 1×
“The ESS is connected at the same point of connection of the PV inverter and its input/ output power is also real-time monitored [15].”
BackgroundImproved Low Voltage Grid-Integration of Photovoltaic Systems in Germany
Stetz, T., Marten, F., & Braun, M. (2013) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2012.2198925 · Cited by 466 · cited 3×
“In Germany, the vast majority of PV plants, about 13 GW, are connected at the LV grid, causing overvoltage events in different areas during the year [5].”
BackgroundInfluentialResidential photovoltaic energy storage system
Chiang, S. J., Chang, K. T., & Yen, C. Y. (1998) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.678996 · Cited by 459 · cited 1×
“Some alternative solutions to active power curtailment may involve domestic load shifting, to increase local consumption, and energy storage [7], [8].”
BackgroundPV self-consumption optimization with storage and Active DSM for the residential sector
Castillo-Cagigal, M., Caamaño-Martín, E., Matallanas, E., Masa-Bote, D., Gutiérrez, A., Monasterio-Huelin, F., & Jiménez-Leube, J. (2011) · Solar Energy · doi:10.1016/j.solener.2011.06.028 · Cited by 308
Demand profile study of battery electric vehicle under different charging options
Marra, F., Yang, G. Y., Larsen, E., Rasmussen, C. N., & You, S. (2012) · 2012 IEEE Power and Energy Society General Meeting · doi:10.1109/pesgm.2012.6345063 · Cited by 168 · cited 3×
“According to [18], to operate the ESS battery within a linear SOC region and to avoid deep discharge cycles, the battery should be oversized in relation to the usable energy window identified with simulations.”
BackgroundMethodInfluentialSelf-citationGlobal modeling of different vehicles
Chen, K., Bouscayrol, A., Berthon, A., Delarue, P., Hissel, D., & Trigui, R. (2009) · IEEE Vehicular Technology Magazine · doi:10.1109/mvt.2009.932540 · Cited by 94 · cited 1×
“However, due to the better performances of Li-ion battery chemistries in terms of lifetime, energy-to-weight ratio, self-discharge rate and charge- discharge efficiency, this technology is adopted for the ESS in this paper [16].”
Method
Cited by
A Review of Architectures and Concepts for Intelligence in Future Electric Energy Systems
Strasser, T., Andren, F., Kathan, J., Cecati, C., Buccella, C., Siano, P., Leitao, P., Zhabelova, G., Vyatkin, V., Vrba, P., et al. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2361486 · Cited by 572
Zeraati, M., Hamedani Golshan, M. E., & Guerrero, J. M. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2636217 · Cited by 395
Zidar, M., Georgilakis, P. S., Hatziargyriou, N. D., Capuder, T., & Škrlec, D. (2016) · IET Generation, Transmission & Distribution · doi:10.1049/iet-gtd.2015.0447 · Cited by 275
Li, J., Lin, J., Song, Y., Xing, X., & Fu, C. (2019) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2018.2868827 · Cited by 256
Zeraati, M., Hamedani Golshan, M. E., & Guerrero, J. M. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2749623 · Cited by 232
“The main strategies are on-load tap changing (OLTC) transformer [6], active power curtailment (APC) of PV systems [7], reactive power management [8], and energy storage systems [9].”
Methods and strategies for overvoltage prevention in low voltage distribution systems with PV
Hashemi, S., & Østergaard, J. (2017) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2016.0277 · Cited by 212
Self-citationRajabi, A., Elphick, S., David, J., Pors, A., & Robinson, D. (2022) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2022.112365 · Cited by 70
PV-integration strategies for low voltage networks
Heinrich, C., Fortenbacher, P., Fuchs, A., & Andersson, G. (2016) · 2016 IEEE International Energy Conference (ENERGYCON) · doi:10.1109/energycon.2016.7514141 · Cited by 23
Metadata
- Authors
- Marra, F., Yang, G., Traeholt, C., Ostergaard, J., & Larsen, E.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2014-03
- Volume
- 5
- Issue
- 2
- Pages
- 974-981
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2066093562
- Cited by
- 195
- References
- 15
- FWCI
- 13.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.