Cited by 273Smart Grid Energy ManagementBuilding Energy and Comfort OptimizationFrequency Control in Power Systems

The DOI matches its Crossref record.

Ancillary Service to the Grid Through Control of Fans in Commercial Building HVAC Systems

Hao, He, Lin, Yashen, Kowli, Anupama S., Barooah, Prabir, Meyn, Sean·2014·IEEE Transactions on Smart Grid

Abstract

The thermal storage potential in commercial buildings is an enormous resource for providing various ancillary services to the grid. In this paper, we show how fans in Heating, Ventilation, and Air Conditioning (HVAC) systems of commercial buildings alone can provide substantial frequency regulation service, with little change in their indoor environments. A feedforward architecture is proposed to control the fan power consumption to track a regulation signal. The proposed control scheme is then tested through simulations based on a calibrated high fidelity non-linear model of a building. Model parameters are identified from data collected in Pugh Hall, a commercial building located on the University of Florida campus. For the HVAC system under consideration, numerical experiments demonstrate how up to 15% of the rated fan power can be deployed for regulation purpose while having little effect on the building indoor temperature. The regulation signal that can be successfully tracked is constrained in the frequency band [1/τ0,1/τ1], where τ0 ≈ 3 minutes and τ1 ≈ 8 seconds. Our results indicate that fans in existing commercial buildings in the U.S. can provide about 70% of the current national regulation reserve requirements in the aforementioned frequency band. A unique advantage of the proposed control scheme is that assessing the value of the ancillary service provided is trivial, which is in stark contrast to many demand-response programs.

Overview

Integrity signals

Registry

Crossref · 10.1109/tsg.2014.2322604

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • HVAC systems employ variable frequency drives (VFD), the speed and power of which can be quickly and continuously adjusted, following the regulation signal provided by the system operator in order to provide regulation reserve.

    “Also, HVAC systems employ variable frequency drives (VFD), the speed and power of which can be quickly and continuously adjusted, following the regulation signal provided by the system operator in order to provide regulation reserve [65].”

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 24

  1. 10.1016/j.enconman.2008.12.012 · DOI
  2. kundu, 2011, Modeling and control of thermostatically controlled loads, Proc 17th Power Syst Computation Conf
  3. 10.1109/Allerton.2013.6736573 · DOI
  4. braun, 1990, Reducing energy costs and peak electrical demand through optimal control of building thermal storage, ASHRAE Trans, 96, 876
  5. 10.1109/CDC.2010.5717458 · DOI
  6. watson, 2006, Strategies for demand response in commercial buildings, Proc ACEEE 2006 Summer Study on Energy Efficiency in Buildings, 287
  7. kiliccote, 2012, Field testing of automated demand response for integration of renewable resources in california's ancillary services market for regulation products, LBNL Tech Report
  8. 10.2172/1172955 · DOI
  9. 10.1115/1.2888063 · DOI
  10. 10.1109/ACC.2013.6579881 · DOI
  11. 10.1109/TPWRS.2007.901598 · DOI
  12. 2010, Storage Participation in ERCOT
  13. 10.1109/CDC.2010.5717327 · DOI
  14. helman, 2010, Resource and transmission planning to achieve a 33% rps in california-iso modeling tools and planning framework, Proc FERC Tech Conf Planning Models Softw
  15. 10.1109/PES.2009.5275922 · DOI
  16. 10.1109/TPWRS.2007.901489 · DOI
  17. 0, Buildings Energy Data Book
  18. 0, PJM Regulation Data
  19. 10.1109/ACC.2012.6315247 · DOI
  20. 2008, The ASHRAE Handbook HVAC Systems and Equipment (SI Edition)
  21. 10.1016/j.applthermaleng.2003.11.008 · DOI
  22. 10.1109/CDC.2012.6425958 · DOI
  23. 0, How Much Electric Supply Capacity is Needed to Keep U S Electricity Grids Reliable?
  24. 2008, ?Commercial buildings energy consumption survey (CBECS) Overview of commercial buildings 2003 ?

Cited by

Sorted by citations

Metadata

Authors
Hao, H., Lin, Y., Kowli, A. S., Barooah, P., & Meyn, S.
Affiliations
  • University of California, Berkeley (US)
  • University of Florida (US)
  • Indian Institute of Technology Bombay (IN)
Venue
IEEE Transactions on Smart Grid
Published
2014-07
Volume
5
Issue
4
Pages
2066-2074
ISSN
  • 1949-3053 (ISSN-L)
  • 1949-3061
OpenAlex
W2160327646
Cited by
273
References
0
Citations by year
2026: 7 · 2025: 15 · 2024: 9 · 2023: 16 · 2022: 15 · 2021: 16 · 2020: 30 · 2019: 22 · 2018: 38 · 2017: 40 · 2016: 38 · 2015: 25 · 2014: 2
FWCI
18.58
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Smart Grid (publishedVersion)
  • DSpace (IIT Bombay) (submittedVersion)
Funders
National Science Foundation (CNS-0931885, ECCS-0925534)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Smart Grid Energy Management
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Frequency Control in Power Systems
Keywords
ancillary services, frequency regulation, commercial buildings, thermal energy storage, feedforward control, building energy simulation, parameter estimation, indoor temperature, demand response

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review