The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Quickest Detection of False Data Injection Attack in Wide-Area Smart Grids
Abstract
We consider the sequential (i.e., online) detection of false data injection attacks in smart grid, which aims to manipulate the state estimation procedure by injecting malicious data to the monitoring meters. The unknown parameters in the system, namely the state vector, injected malicious data and the set of attacked meters pose a significant challenge for designing a robust, computationally efficient, and high-performance detector. We propose a sequential detector based on the generalized likelihood ratio to address this challenge. Specifically, the proposed detector is designed to be robust to a variety of attacking strategies, and load situations in the power system, and its computational complexity linearly scales with the number of meters. Moreover, it considerably outperforms the existing first-order cumulative sum detector in terms of the average detection delay and robustness to various attacking strategies. For wide-area monitoring in smart grid, we further develop a distributed sequential detector using an adaptive sampling technique called level-triggered sampling. The resulting distributed detector features single bit per sample in terms of the communication overhead, while preserving the high performance of the proposed centralized detector.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detection of Abrupt Changes: Theory and Application
Riedel, K. S. (1994) · Technometrics · doi:10.1080/00401706.1994.10485821 · Cited by 3,518
Procedures for Reacting to a Change in Distribution
Lorden, G. (1971) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177693055 · Cited by 1,351
A Survey on Smart Grid Communication Infrastructures: Motivations, Requirements and Challenges
Yan, Y., Qian, Y., Sharif, H., & Tipper, D. (2013) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2012.021312.00034 · Cited by 1,315
False data injection attacks against state estimation in electric power grids
Liu, Y., Ning, P., & Reiter, M. K. (2009) · Proceedings of the 16th ACM conference on Computer and communications security · doi:10.1145/1653662.1653666 · Cited by 1,285
Optimal Stopping Times for Detecting Changes in Distributions
Moustakides, G. V. (1986) · The Annals of Statistics · doi:10.1214/aos/1176350164 · Cited by 1,020
Malicious Data Attacks on the Smart Grid
Kosut, O., Jia, L., Thomas, R. J., & Tong, L. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2163807 · Cited by 784
Wide-Area Monitoring, Protection, and Control of Future Electric Power Networks
Terzija, V., Valverde, G., Cai, D., Regulski, P., Madani, V., Fitch, J., Skok, S., Begovic, M. M., & Phadke, A. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2060450 · Cited by 761
Bad data analysis for power system state estimation
Handschin, E., Schweppe, F. C., Kohlas, J., & Fiechter, A. (1975) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/t-pas.1975.31858 · Cited by 603
Modeling Load Redistribution Attacks in Power Systems
Yuan, Y., Li, Z., & Ren, K. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2123925 · Cited by 545
Distributed Robust Power System State Estimation
Kekatos, V., & Giannakis, G. B. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2219629 · Cited by 521
Cited by
Hossain, E., Khan, I., Un-Noor, F., Sikander, S. S., & Sunny, M. S. H. (2019) · IEEE Access · doi:10.1109/access.2019.2894819 · Cited by 513
A Survey on State Estimation Techniques and Challenges in Smart Distribution Systems
Dehghanpour, K., Wang, Z., Wang, J., Yuan, Y., & Bu, F. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2870600 · Cited by 485
Cyber‐physical attacks and defences in the smart grid: a survey
He, H., & Yan, J. (2016) · IET Cyber-Physical Systems: Theory & Applications · doi:10.1049/iet-cps.2016.0019 · Cited by 454
State of the art of cyber-physical systems security: An automatic control perspective
Zacchia Lun, Y., D’Innocenzo, A., Smarra, F., Malavolta, I., & Di Benedetto, M. D. (2019) · Journal of Systems and Software · doi:10.1016/j.jss.2018.12.006 · Cited by 211
A Systematic Analysis of Enhancing Cyber Security Using Deep Learning for Cyber Physical Systems
Gaba, S., Budhiraja, I., Kumar, V., Martha, S., Khurmi, J., Singh, A., Singh, K. K., Askar, S. S., & Abouhawwash, M. (2024) · IEEE Access · doi:10.1109/access.2023.3349022 · Cited by 62
Metadata
- Authors
- Li, S., Yilmaz, Y., & Wang, X.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2015-11
- Volume
- 6
- Issue
- 6
- Pages
- 2725-2735
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2022229650
- Cited by
- 272
- References
- 19
- FWCI
- 16.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quickest Detection of False Data Injection Attack in Wide-Area Smart Grids. https://app.cochat.ai/papers/10.1109/tsg.2014.2374577
- The paper
- Li, S., Yilmaz, Y., & Wang, X. (2015). Quickest Detection of False Data Injection Attack in Wide-Area Smart Grids. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2014.2374577
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.