The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Coordinated Control Based on Bus-Signaling and Virtual Inertia for Islanded DC Microgrids
Open accessAbstract
A low-voltage islanded dc microgrid contains a number of renewable energy sources, local loads, and energy storage systems (ESS). To avoid the over-charging and over-discharging situations of ESS, a coordinated control strategy should be used in islanded dc microgrids. In this paper, a novel bus-signaling method (BSM) is proposed to achieve autonomous coordinated performance of system according to different state of charge conditions. Additionally, a secondary coordinated control is introduced to restore the voltage deviation produced by primary control level without decaying coordinated performance. The proposed control algorithm and controller implementation based on BSM are also presented. Finally, real-time simulation results show the feasibility of the proposed approach by presenting the operation of an islanded dc microgrid in different testing scenarios.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Self-citationDu, Y., Zhou, X., Bai, S., Lukic, S., & Huang, A. (2010) · 2010 Twenty-Fifth Annual IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2010.5433359 · Cited by 314
Cited by
DC Microgrid Planning, Operation, and Control: A Comprehensive Review
Al-Ismail, F. S. (2021) · IEEE Access · doi:10.1109/access.2021.3062840 · Cited by 542
Primary and secondary control in DC microgrids: a review
GAO, F., KANG, R., CAO, J., & YANG, T. (2019) · Journal of Modern Power Systems and Clean Energy · doi:10.1007/s40565-018-0466-5 · Cited by 314
A brief review on microgrids: Operation, applications, modeling, and control
Shahgholian, G. (2021) · International Transactions on Electrical Energy Systems · doi:10.1002/2050-7038.12885 · Cited by 280
A review on overall control of DC microgrids
Kumar, J., Agarwal, A., & Agarwal, V. (2019) · Journal of Energy Storage · doi:10.1016/j.est.2018.11.013 · Cited by 257
Metadata
- Authors
- Wu, D., Tang, F., Dragicevic, T., Guerrero, J. M., & Vasquez, J. C.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2015-11
- Volume
- 6
- Issue
- 6
- Pages
- 2627-2638
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W1973622203
- Cited by
- 204
- References
- 2
- FWCI
- 17.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coordinated Control Based on Bus-Signaling and Virtual Inertia for Islanded DC Microgrids. https://app.cochat.ai/papers/10.1109/tsg.2014.2387357
- The paper
- Wu, D., Tang, F., Dragicevic, T., Guerrero, J. M., & Vasquez, J. C. (2015). Coordinated Control Based on Bus-Signaling and Virtual Inertia for Islanded DC Microgrids. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2014.2387357
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.