Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 19 of the 21 references it cites were found in a registry or an index.

Developing a Hybrid Intrusion Detection System Using Data Mining for Power Systems

Pan, Shengyi, Morris, Thomas, Adhikari, Uttam · 2015 · IEEE Transactions on Smart Grid

Abstract

Synchrophasor systems provide an immense volume of data for wide area monitoring and control of power systems to meet the increasing demand of reliable energy. The construction of traditional intrusion detection systems (IDSs) that use manually created rules based upon expert knowledge is knowledge-intensive and is not suitable in the context of this big data problem. This paper presents a systematic and automated approach to build a hybrid IDS that learns temporal state-based specifications for power system scenarios including disturbances, normal control operations, and cyber-attacks. A data mining technique called common path mining is used to automatically and accurately learn patterns for scenarios from a fusion of synchrophasor measurement data, and power system audit logs. As a proof of concept, an IDS prototype was implemented and validated. The IDS prototype accurately classifies disturbances, normal control operations, and cyber-attacks for the distance protection scheme for a two-line three-bus power transmission system.

Overview

Integrity signals

Registry

Crossref · 10.1109/tsg.2015.2409775

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 21 references

Research works printed but not linked: 4

  1. 2014, NISTIR 7628 Guidelines for Smart Grid Cyber Security Vol 1 Smart Grid Cybersecurity Strategy Architecture and High-Level Requirements
  2. 2010, NERC Standards Critical Infrastructure Protection CIP-002-3 Through CIP-009-3
  3. 2007, A Systems View of the Modern Grid
  4. nylén, 1979, Auto-reclosing, ASEA J, 52, 127

Cited by

See all 517

Metadata

Authors
Pan, S., Morris, T., & Adhikari, U.
Affiliations
Mississippi State University (US)
Venue
IEEE Transactions on Smart Grid
Published
2015-11
Volume
6
Issue
6
Pages
3104-3113
ISSN
  • 1949-3053 (ISSN-L)
  • 1949-3061
OpenAlex
W1991510770
Cited by
457
References
21
Citations by year
2026: 27 · 2025: 29 · 2024: 43 · 2023: 50 · 2022: 48 · 2021: 68 · 2020: 46 · 2019: 58 · 2018: 45 · 2017: 28 · 2016: 12 · 2015: 2
FWCI
26.80
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Smart Grid (publishedVersion)
Funders
U.S. National Science Foundation (DUE-1344369, DUE-1315726)
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Smart Grid Security and Resilience
  • Physical Sciences › Computer Science › Computer Networks and Communications › Network Security and Intrusion Detection
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power System Optimization and Stability
Keywords
intrusion detection systems, power system cybersecurity, cyberattack detection, disturbance classification, distance protection, wide-area monitoring, hybrid IDS

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Developing a Hybrid Intrusion Detection System Using Data Mining for Power Systems. https://app.cochat.ai/papers/10.1109/tsg.2015.2409775
The paper
Pan, S., Morris, T., & Adhikari, U. (2015). Developing a Hybrid Intrusion Detection System Using Data Mining for Power Systems. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2015.2409775

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.