The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Optimal Operation of Distribution Networks Considering Energy Storage Devices
Open accessAbstract
This paper presents a mixed-integer second-order cone programing (MISOCP) model to solve the optimal operation problem of radial distribution networks (DNs) with energy storage. The control variables are the active and reactive generated power of dispatchable distributed generators (DGs), the number of switchable capacitor bank units in operation, the tap position of the voltage regulators and on-load tap-changers, and the operation state of the energy storage devices. The objective is to minimize the total cost of energy purchased from the distribution substation and the dispatchable DGs. The steady-state operation of the DN is modeled using linear and second-order cone programing. The use of an MISOCP model guarantees convergence to optimality using existing optimization software. A mixed-integer linear programing (MILP) formulation for the original model is also presented in order to show the accuracy of the proposed MISOCP model. An 11-node test system and a 42-node real system were used to demonstrate the effectiveness of the proposed MISOCP and MILP models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Branch Flow Model: Relaxations and Convexification—Part I
Farivar, M., & Low, S. H. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2255317 · Cited by 1,541
Cited by
Das, C. K., Bass, O., Kothapalli, G., Mahmoud, T. S., & Habibi, D. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.03.068 · Cited by 656
Li, P., Ji, H., Wang, C., Zhao, J., Song, G., Ding, F., & Wu, J. (2017) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2017.2686009 · Cited by 447
Stecca, M., Ramirez Elizondo, L., Batista Soeiro, T., Bauer, P., & Palensky, P. (2020) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2020.2981832 · Cited by 297
Prabawa, P., & Choi, D.-H. (2021) · IEEE Access · doi:10.1109/access.2021.3109621 · Cited by 31
Voltage Regulation Strategies in Photovoltaic-Energy Storage System Distribution Network: A Review
Dong, Q., Song, X., Gong, C., Hu, C., Rui, J., Wang, T., Xia, Z., & Wang, Z. (2025) · Energies · doi:10.3390/en18112740 · Cited by 23
Metadata
- Authors
- Macedo, L. H., Franco, J. F., Rider, M. J., & Romero, R.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2015-11
- Volume
- 6
- Issue
- 6
- Pages
- 2825-2836
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2024956408
- Cited by
- 192
- References
- 1
- FWCI
- 10.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal Operation of Distribution Networks Considering Energy Storage Devices. https://app.cochat.ai/papers/10.1109/tsg.2015.2419134
- The paper
- Macedo, L. H., Franco, J. F., Rider, M. J., & Romero, R. (2015). Optimal Operation of Distribution Networks Considering Energy Storage Devices. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2015.2419134
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.