The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Bilevel Model for Analyzing Coordinated Cyber-Physical Attacks on Power Systems
Abstract
This paper analyzes a coordinated cyber-physical attack on power systems, which could lead to undetectable line outages. Coordinated with physical attacks that cause line outages, the two-step cyberattacks comprising topology preserving and load redistribution attacks could mask and potentially exasperate outages to trigger cascading failures. These coordinated cyber-physical attacks are analyzed in a proposed bilevel model, which aims at identifying the most damaging and undetectable physical attacks constrained by attackers' total budget. After being transformed into a mixed-integer linear programming problem, the proposed bilevel model is solved by a rigorous two-stage solution approach. This paper also discusses the relevant countermeasure strategies. The proposed model, the solution algorithm, and the effectiveness of countermeasures are examined by case studies based on the IEEE 14- and 118-bus test systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power system reliability evaluation with SCADA cybersecurity considerations
Zhang, Y., Wang, L., Xiang, Y., & Ten, C.-W. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2396994 · Cited by 239
Cited by
False Data Injection on State Estimation in Power Systems—Attacks, Impacts, and Defense: A Survey
Deng, R., Xiao, G., Lu, R., Liang, H., & Vasilakos, A. V. (2017) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2016.2614396 · Cited by 553
Cyber‐physical attacks and defences in the smart grid: a survey
He, H., & Yan, J. (2016) · IET Cyber-Physical Systems: Theory & Applications · doi:10.1049/iet-cps.2016.0019 · Cited by 454
Yohanandhan, R. V., Elavarasan, R. M., Manoharan, P., & Mihet-Popa, L. (2020) · IEEE Access · doi:10.1109/access.2020.3016826 · Cited by 391
State of the art of cyber-physical systems security: An automatic control perspective
Zacchia Lun, Y., D’Innocenzo, A., Smarra, F., Malavolta, I., & Di Benedetto, M. D. (2019) · Journal of Systems and Software · doi:10.1016/j.jss.2018.12.006 · Cited by 211
False data attack models, impact analyses and defense strategies in the electricity grid
Liu, X., & Li, Z. (2017) · The Electricity Journal · doi:10.1016/j.tej.2017.04.001 · Cited by 57
Self-citation
Metadata
- Authors
- Li, Z., Shahidehpour, M., Alabdulwahab, A., & Abusorrah, A.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2016-09
- Volume
- 7
- Issue
- 5
- Pages
- 2260-2272
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2517303124
- Cited by
- 249
- References
- 1
- FWCI
- 18.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bilevel Model for Analyzing Coordinated Cyber-Physical Attacks on Power Systems. https://app.cochat.ai/papers/10.1109/tsg.2015.2456107
- The paper
- Li, Z., Shahidehpour, M., Alabdulwahab, A., & Abusorrah, A. (2016). Bilevel Model for Analyzing Coordinated Cyber-Physical Attacks on Power Systems. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2015.2456107
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.