Protection Coordination for Microgrids With Grid-Connected and Islanded Capabilities Using Communication Assisted Dual Setting Directional Overcurrent Relays
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
This paper proposes a communication assisted dual setting relay protection scheme for micro-grids with grid connected and islanded capability. Previous work on dual setting relays has been applied to grid connected distributed generation systems only, but one major shortcoming is the failure of the backup scheme to operate in a coordinated manner. The proposed scheme relies on the use of dual setting directional overcurrent relays that are capable of operating in both forward and reverse directions, with different settings, and with a low bandwidth communication to maintain proper protection coordination. The problem is formulated as a non-linear constrained programming problem where the relay settings are optimally determined to minimize the overall relay operating time for primary and backup operation. The scheme is tested on a modified version of the IEEE 30 bus test system equipped with distributed generation and with capability of operating in an islanded mode. The proposed scheme is compared against the conventional scheme and the results show that it is capable of overcoming the problem of infeasibility, experienced by the conventional method, without the need of installing fault current limiters. Furthermore, it achieves remarkable reduction in both the primary and backup relay operating times, which was reflected in a reduction in the total relay operating time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137 · cited 1×
“2546961 approaches for micro-grids have been proposed which are simple and require no communication [1]–[3].”
BackgroundMicrogrid Protection Using Communication-Assisted Digital Relays
Sortomme, E., Venkata, S. S., & Mitra, J. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2009.2035810 · Cited by 537
Optimal Protection Coordination for Microgrids With Grid-Connected and Islanded Capability
Najy, W., Zeineldin, H. H., & Woon, W. L. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2192893 · Cited by 428 · cited 3×
“Micro-grid protection schemes that do not require or rely on communication have been proposed in [7]–[10].”
BackgroundMethodSelf-citationProtection Principles for Future Microgrids
Laaksonen, H. J. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2066990 · Cited by 380 · cited 1×
“In [12], a coordinated protection scheme that relies on directional overcurrent relays and frequency relays is proposed that utilizes high speed communication to”
BackgroundUstun, T. S., Ozansoy, C., & Zayegh, A. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2185072 · Cited by 335 · cited 2×
“ating current is updated depending on the micro-grid mode of operation, is proposed in [14].”
BackgroundA Protection Strategy and Microprocessor-Based Relay for Low-Voltage Microgrids
Zamani, M. A., Sidhu, T. S., & Yazdani, A. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2120628 · Cited by 324 · cited 3×
“As stated in [7], one of the salient features of the proposed method is that it does not require communication or adaptive protective devices; however, the proposed method is applicable to low voltage small scale micro-grids.”
BackgroundMethodDroop-Free Distributed Control for AC Microgrids
Nasirian, V., Shafiee, Q., Guerrero, J. M., Lewis, F. L., & Davoudi, A. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2414457 · Cited by 301 · cited 2×
“Such techniques suffer from poor reactive power sharing and the capability of handling nonlinear as well as frequency and voltage dependent loads [4].”
BackgroundAn Improved Droop Control Strategy for Reactive Power Sharing in Islanded Microgrid
Han, H., Liu, Y., Sun, Y., Su, M., & Guerrero, J. M. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2332181 · Cited by 301 · cited 1×
“2546961 approaches for micro-grids have been proposed which are simple and require no communication [1]–[3].”
BackgroundData-Mining Model Based Intelligent Differential Microgrid Protection Scheme
Kar, S., Samantaray, S. R., & Zadeh, M. D. (2017) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2380432 · Cited by 295 · cited 1×
“A differential protection strategy is developed using data mining techniques which relies on communicating measurements between two relays [19], [20].”
Micallef, A., Apap, M., Spiteri-Staines, C., Guerrero, J. M., & Vasquez, J. C. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2291912 · Cited by 281 · cited 1×
“To overcome these problems, other micro-grid control techniques have been proposed that rely on a communication infrastructure [4]–[6].”
BackgroundCasagrande, E., Woon, W. L., Zeineldin, H. H., & Svetinovic, D. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2251017 · Cited by 276 · cited 1×
“A differential protection strategy is developed using data mining techniques which relies on communicating measurements between two relays [19], [20].”
Self-citationZeineldin, H. H., Sharaf, H. M., Ibrahim, D. K., & El-Zahab, E. E.-D. A. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2357813 · Cited by 266 · cited 6×
“The objective should be achieved while fulfilling the following set of constraints for both modes of operation [22]:”
BackgroundMethodResultSelf-citationA Communication-Assisted Protection Strategy for Inverter-Based Medium-Voltage Microgrids
Zamani, M., Yazdani, A., & Sidhu, T. S. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2211045 · Cited by 210 · cited 1×
“proposed for micro-grids in [13].”
Li, X., Dysko, A., & Burt, G. M. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2320365 · Cited by 205
Reactive Power Sharing in Islanded Microgrids Using Adaptive Voltage Droop Control
Mahmood, H., Michaelson, D., & Jiang, J. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2399232 · Cited by 185
Adaptive Protection and Microgrid Control Design for Hailuoto Island
Laaksonen, H., Ishchenko, D., & Oudalov, A. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2287672 · Cited by 177 · cited 1×
“An adaptive protection and control scheme with IEC 61850 based communications is developed for microgrids where the relay settings are modified depending on the mode of operation [16].”
Multiterminal Hybrid Protection of Microgrids Over Wireless Communications Network
Ustun, T. S., & Khan, R. H. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2406886 · Cited by 122 · cited 4×
“Two key communication issues that highly influence the performance of the micro-grid protection scheme are the communication load and most importantly the reliability [17].”
BackgroundMethodInfluentialImplementing and Testing $d$– $q$ WPT-Based Digital Protection for Microgrid Systems
Saleh, S. A., Ahshan, R., Abu‐Khaizaran, M., Alsayid, B. A., & Rahman, M. A. (2013) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2290814 · Cited by 71 · cited 1×
“A new digital protection relay that utilizes the wavelet packet transform is proposed to classify and detect fault events during islanded and grid connected operation [8], [9].”
Signature-Coordinated Digital Multirelay Protection for Microgrid Systems
Saleh, S. A. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2285978 · Cited by 68 · cited 2×
“A new digital protection relay that utilizes the wavelet packet transform is proposed to classify and detect fault events during islanded and grid connected operation [8], [9].”
BackgroundKahrobaeian, A., & Mohamed, Y. A. I. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2217763 · Cited by 24
Metadata
- Authors
- Sharaf, H. M., Zeineldin, H. H., & El-Saadany, E.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2018-01
- Volume
- 9
- Issue
- 1
- Pages
- 143-151
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2316087006
- Cited by
- 236
- References
- 20
- FWCI
- 14.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.