A New Directional Element for Microgrid Protection
The DOI matches its Crossref record.
Abstract
With protective relays exclusive for microgrid applications yet to be developed, microgrids are currently limited mostly to directional overcurrent relays (DOCRs) for protection. This paper unveils that the long-known small fault current of electronically coupled distributed generation (DG) units is merely one of several phenomena that DOCRs suffer from; the current magnitude in microgrids with DG units may even provide misleading indications of fault conditions. More important, commercial-grade torque- and impedance-based directional elements are shown to be adversely affected by the fault behavior of DG units. The misoperation may include incorrect fault direction identification or deactivation of directional elements by false detection of loss-of-voltage condition, ruling out existing impedance relays as workable solutions for microgrid protection as well. This paper also devises a new directional element that addresses these problems. The proposed element detects the direction of asymmetrical faults using the magnitude and angle of the superimposed negative-sequence impedance. For symmetrical faults, the proposed directional element uses the magnitude of superimposed positive-sequence impedance along with the positive-sequence current and torque angle. PSCAD/EMTDC simulation studies verify the performance of this new method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Central Power Research Institute, Telukunta, V., Pradhan, J., Central Power Research Institute, Agrawal, A., Central Power Research Institute, Singh, M., Central Power Research Institute, Srivani, S. G., & R V College of Engineering (2017) · CSEE Journal of Power and Energy Systems · doi:10.17775/cseejpes.2017.00030 · Cited by 544
Netsanet, S., Zheng, D., Wei, Z., & Teshager, G. (2022) · Frontiers in Energy Research · doi:10.3389/fenrg.2022.826915 · Cited by 5
“Such special characteristics of ADNs result in the commonly used current magnitude-based protection relays (such as overcurrent protection) being less effective in the case of ADNs (Hooshyar and Iravani, 2017; Hooshyar and Iravani, 2018).”
Background
Metadata
- Authors
- Hooshyar, A., & Iravani, R.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2018-11
- Volume
- 9
- Issue
- 6
- Pages
- 6862-6876
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2734470972
- Cited by
- 223
- References
- 0
- FWCI
- 8.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A New Directional Element for Microgrid Protection. https://app.cochat.ai/papers/10.1109/tsg.2017.2727400
- The paper
- Hooshyar, A., & Iravani, R. (2018). A New Directional Element for Microgrid Protection. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2017.2727400
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.