A New Directional Element for Microgrid Protection
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
With protective relays exclusive for microgrid applications yet to be developed, microgrids are currently limited mostly to directional overcurrent relays (DOCRs) for protection. This paper unveils that the long-known small fault current of electronically coupled distributed generation (DG) units is merely one of several phenomena that DOCRs suffer from; the current magnitude in microgrids with DG units may even provide misleading indications of fault conditions. More important, commercial-grade torque- and impedance-based directional elements are shown to be adversely affected by the fault behavior of DG units. The misoperation may include incorrect fault direction identification or deactivation of directional elements by false detection of loss-of-voltage condition, ruling out existing impedance relays as workable solutions for microgrid protection as well. This paper also devises a new directional element that addresses these problems. The proposed element detects the direction of asymmetrical faults using the magnitude and angle of the superimposed negative-sequence impedance. For symmetrical faults, the proposed directional element uses the magnitude of superimposed positive-sequence impedance along with the positive-sequence current and torque angle. PSCAD/EMTDC simulation studies verify the performance of this new method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
Pena, R., Clare, J. C., & Asher, G. M. (1996) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:19960288 · Cited by 2,759 · cited 2×
“A conventional DFIG controller regulates only I+ [21], making the negative-sequence circuit of a DFIG similar to that of an SCIG.”
BackgroundMethodVoltage‐Sourced Converters in Power Systems: Modeling, Control, and Applications
Yazdani, A., & Iravani, R. (2010) · Wiley eBooks · doi:10.1002/9780470551578 · Cited by 2,264
Self-citationSmart Distribution: Coupled Microgrids
Lasseter, R. H. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2114630 · Cited by 1,130 · cited 1×
“3) The microgrid concept was introduced with the promise of integrating more renewable energy sources in the form of distributed generation (DG) [2].”
BackgroundEvaluation of Current Controllers for Distributed Power Generation Systems
Timbus, A., Liserre, M., Teodorescu, R., Rodriguez, P., & Blaabjerg, F. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2012527 · Cited by 934 · cited 1×
“A generic VSC current control includes feedforward compensation of the VSC filter’s grid-side voltage, Vg, at the outputs of the controllers [14].”
BackgroundVoltage-Sourced Converters in Power Systems : Modeling, Control, and Applications
Yazdani, A., & Iravani, R. (2010) · Cited by 831
Self-citationMicrogrids : architectures and control
Hatziargyriou, N. D. (2014) · CERN Document Server (European Organization for Nuclear Research) · Cited by 686
Benchmark systems for network integration of renewable and distributed energy resources
Barsali, S., & Tf, C. C. (2014) · CINECA IRIS Institutial research information system (University of Pisa) · Cited by 609
A Communication-Assisted Protection Strategy for Inverter-Based Medium-Voltage Microgrids
Zamani, M., Yazdani, A., & Sidhu, T. S. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2211045 · Cited by 210
Adaptive Protection and Microgrid Control Design for Hailuoto Island
Laaksonen, H., Ishchenko, D., & Oudalov, A. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2287672 · Cited by 177
Rebirth of negative-sequence quantities in protective relaying with microprocessor-based relays
Calero, F. (2004) · Conference for Protective Relay Engineers · doi:10.1109/cpre.2004.238492 · Cited by 38 · cited 1×
“Thus, it has been increasingly used to detect the direction of asymmetrical faults with the advent of digital relays [25].”
MethodProtection of Distribution Systems with Distributed Energy Resources
Bak‐Jensen, B., Browne, M., Calone, R., González, R. C., Craib, A., Donnart, G., Dumitrașcu, D.-G., Engel, M., Hanuš, R., Høidalen, H. K., et al. (2015) · VBN Forskningsportal (Aalborg Universitet) · Cited by 36
Cited by
Central Power Research Institute, Telukunta, V., Pradhan, J., Central Power Research Institute, Agrawal, A., Central Power Research Institute, Singh, M., Central Power Research Institute, Srivani, S. G., & R V College of Engineering (2017) · CSEE Journal of Power and Energy Systems · doi:10.17775/cseejpes.2017.00030 · Cited by 544
Netsanet, S., Zheng, D., Wei, Z., & Teshager, G. (2022) · Frontiers in Energy Research · doi:10.3389/fenrg.2022.826915 · Cited by 5
“Such special characteristics of ADNs result in the commonly used current magnitude-based protection relays (such as overcurrent protection) being less effective in the case of ADNs (Hooshyar and Iravani, 2017; Hooshyar and Iravani, 2018).”
Background
Metadata
- Authors
- Hooshyar, A., & Iravani, R.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2018-11
- Volume
- 9
- Issue
- 6
- Pages
- 6862-6876
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2734470972
- Cited by
- 223
- References
- 12
- FWCI
- 8.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.