Cited by 76Optimal Power Flow DistributionPower Systems and Renewable EnergyMicrogrid Control and Optimization

Improving Hosting Capacity of Rooftop PVs by Quadratic Control of an LV-Central BSS

Open access
Astero, Poria, Söder, Lennart·2019·IEEE Transactions on Smart Grid

Abstract

High integration of rooftop photovoltaic (PV) plants in distribution systems leads to new technical challenges: reverse-active power and voltage rise in low-voltage (LV) and medium-voltage (MV) grids. These challenges limit the maximum amount of power can be produced by PVs in LV and MV grids, called the hosting capacity (HC). Battery storage systems (BSSs) have been used in many studies to decrease the reverse power and improve the HC by controlling the active power. However, the influence of a central BSS on the HC can be greatly improved by using a quadratic power control, simultaneous active, and reactive power control, and by selecting of the optimal battery size, the converter size, and the place of the central BSS. The effectiveness of the quadratic power control was not seen in previous works due to the fact that grids with one level of voltage without modeling of MV/LV transformers were simulated. This paper develops a method to select the optimal size of the battery and converter unit as well as the optimal place of an LV-central BSS having an optimal quadratic power control. The simulation results show considerable effects of the optimal selection of an LV-central BSS on the HC improvement.

Integrity signals

Registry

Crossref · 10.1109/tsg.2017.2754943

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The placement of a CES is an important factor with respect to its overall performance to improve network performance.

    “The effect of battery and converter sizes on current and power losses is studied, and the placement of the CES was determined to be an important factor with respect to their overall performance to improve network performance.”

Cited by

Sorted by citations

Authors
Astero, P., & Söder, L.
Affiliations
KTH Royal Institute of Technology (SE)
Venue
IEEE Transactions on Smart Grid
Published
2019-01
Volume
10
Issue
1
Pages
919-927
ISSN
  • 1949-3053 (ISSN-L)
  • 1949-3061
OpenAlex
W2760749555
Cited by
76
References
0
Citations by year
2026: 5 · 2025: 8 · 2024: 7 · 2023: 12 · 2022: 11 · 2021: 10 · 2020: 14 · 2019: 4 · 2018: 5
FWCI
2.61
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Smart Grid (publishedVersion)
  • KTH Publication Database DiVA (KTH Royal Institute of Technology) (submittedVersion, other-oa)
Funders
Swedish Energy Agency through the Solar-ERA.NET Project
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
  • Physical Sciences › Energy › Energy Engineering and Power Technology › Power Systems and Renewable Energy
  • Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
Keywords
hosting capacity, rooftop solar, battery storage systems, low-voltage distribution networks, voltage rise, converter sizing, MV/LV transformers, active and reactive power control

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review