The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Distributed Noise-Resilient Secondary Voltage and Frequency Control for Islanded Microgrids
Open accessAbstract
This paper proposes a novel distributed noise-resilient secondary control for voltage and frequency restoration of islanded microgrid inverter-based distributed generations (DGs) with an additive type of noise. The existing distributed methods commonly are designed as secondary control system systems that operate on the assumption of ideal communication networks among DGs. However, the channels are prone to stochastic noise, whereas each DG obtains noisy measurements of the states of its neighbors via environmental noises. The existing distributed noise-resilient methods, ignore a complete model of the system. In contrast, this paper proposes consensus protocols that take into account both the noisy measurements and a complete nonlinear model of the system, examines the mean-square average consensus for voltage and frequency restoration of islanded ac microgrids in an uncertain environment, and provides accurate proportional real power sharing. Our proposed consensus protocol contains two parts: the state feedback of the agent and the relative states of the DG and its neighboring DGs. Finally, simulation studies are carried out in MATLAB/SimPowerSystems to evaluate the performance of the control laws. Simulation results and comparison with previous work reveals the effectiveness of the proposed method in regulating microgrid voltage and frequency and providing accurate proportional real power sharing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137 · cited 1×
“(autonomous) modes of operation [2], [3].”
Cited by
Distributed Control Strategies for Microgrids: An Overview
Espina, E., Llanos, J., Burgos-Mellado, C., Cardenas-Dobson, R., Martinez-Gomez, M., & Saez, D. (2020) · IEEE Access · doi:10.1109/access.2020.3032378 · Cited by 415
Support Vector Machine-Based Islanding and Grid Fault Detection in Active Distribution Networks
Baghaee, H. R., Mlakic, D., Nikolovski, S., & Dragicevic, T. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2916621 · Cited by 235
Self-citationEthical frameworks for machine learning in sensitive healthcare applications
Javed, H., Muqeet, H. A., Javed, T., Rehman, A. U., & Sadiq, R. (2024) · IEEE Access · doi:10.1109/access.2023.3340884 · Cited by 35
Metadata
- Authors
- Dehkordi, N. M., Baghaee, H. R., Sadati, N., & Guerrero, J. M.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2019-07
- Volume
- 10
- Issue
- 4
- Pages
- 3780-3790
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2802621841
- Cited by
- 214
- References
- 1
- FWCI
- 16.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Distributed Noise-Resilient Secondary Voltage and Frequency Control for Islanded Microgrids. https://app.cochat.ai/papers/10.1109/tsg.2018.2834951
- The paper
- Dehkordi, N. M., Baghaee, H. R., Sadati, N., & Guerrero, J. M. (2019). Distributed Noise-Resilient Secondary Voltage and Frequency Control for Islanded Microgrids. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2018.2834951
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.