The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Real-Time Local Volt/Var Control Under External Disturbances With High PV Penetration
Open accessAbstract
Volt/var control (VVC) of smart PV inverter is becoming one of the most widely used solutions to address the voltage challenges associated with high PV penetration. This paper focuses on the local droop VVC recommended by the grid integration standards IEEE1547, rule21, and addresses their major challenges, i.e., appropriate parameters selection under changing conditions, and the control being vulnerable to instability (or voltage oscillations) and significant steady state error (SSE). This is achieved by proposing a two-layer local real-time adaptive VVC that has two major features: 1) it is able to ensure both low SSE and control stability simultaneously without compromising either, and 2) it dynamically adapts its parameters to ensure good performance in a wide range of external disturbances such as sudden cloud cover, cloud intermittency, and substation voltage changes. A theoretical analysis and convergence proof of the proposed control is also discussed. The proposed control is implementation friendly as it fits well within the integration standard framework and depends only on the local bus information. The performance is compared to existing droop VVC methods in several scenarios on a large unbalanced 3-phase feeder with detailed secondary side modeling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Horn, R. A., & Johnson, C. R. (2012) · doi:10.1017/cbo9781139020411 · Cited by 4,642
Photovoltaic and solar power forecasting for smart grid energy management
Wan, C., Zhao, J., Song, Y., Xu, Z., Lin, J., & Hu, Z. (2015) · CSEE Journal of Power and Energy Systems · doi:10.17775/cseejpes.2015.00046 · Cited by 654
Antoniadou-Plytaria, K. E., Kouveliotis-Lysikatos, I. N., Georgilakis, P. S., & Hatziargyriou, N. D. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2679238 · Cited by 545
Cited by
Review of Challenges and Research Opportunities for Voltage Control in Smart Grids
Sun, H., Guo, Q., Qi, J., Ajjarapu, V., Bravo, R., Chow, J., Li, Z., Moghe, R., Nasr-Azadani, E., Tamrakar, U., et al. (2019) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2897948 · Cited by 496
Self-citationA Data-Driven Multi-Agent Autonomous Voltage Control Framework Using Deep Reinforcement Learning
Wang, S., Duan, J., Shi, D., Xu, C., Li, H., Diao, R., & Wang, Z. (2020) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.2990179 · Cited by 315
Xu, R., Zhang, C., Xu, Y., Dong, Z., & Zhang, R. (2022) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2021.3126761 · Cited by 83
Rajabi, A., Elphick, S., David, J., Pors, A., & Robinson, D. (2022) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2022.112365 · Cited by 70
Gui, Y., Nainar, K., Ciontea, C.-I., Bendtsen, J. D., Iov, F., Shahid, K., & Stoustrup, J. (2023) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2023.109022 · Cited by 39
Metadata
- Authors
- Singhal, A., Ajjarapu, V., Fuller, J., & Hansen, J.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2019-07
- Volume
- 10
- Issue
- 4
- Pages
- 3849-3859
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2762453531
- Cited by
- 158
- References
- 3
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-Time Local Volt/Var Control Under External Disturbances With High PV Penetration. https://app.cochat.ai/papers/10.1109/tsg.2018.2840965
- The paper
- Singhal, A., Ajjarapu, V., Fuller, J., & Hansen, J. (2019). Real-Time Local Volt/Var Control Under External Disturbances With High PV Penetration. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2018.2840965
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.