A Novel ANFIS-Based Islanding Detection for Inverter-Interfaced Microgrids
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
This paper presents a new islanding detection strategy for low-voltage inverter-interfaced microgrids based on adaptive neuro-fuzzy inference system (ANFIS). The proposed islanding detection method exploits the pattern recognition capability of ANFIS and its nonlinear mapping of relation between inputs. The ANFIS monitors seven inputs measured at point of common coupling (PCC), namely root-mean square (RMS) of voltage and current (RMS and RMSI), total harmonic distortion (THD) of voltage and current (THD and THDI), frequency (f), and active and reactive powers (F, Q) that are experimentally obtained based on practical measurement in a real-life microgrid. The proposed method is composed of passive monitoring of the mentioned inputs. It does not influence power quality (PQ) and considerably decreases non detection zones (NDZs). In order to cover as many situations as possible, minimize false tripping and still remain selective; type and number of samples are introduced. Here, one of the primary goals is reducing NDZ while keeping PQ in order. Based on the sampled frequency and number of samples, we find that the proposed method has less detection time and better accuracy when compared to the reported methods. Simulations performed in MATLAB/Simulink software environment and several tests performed based on different active load conditions and multiple distributed generation, prove the effectiveness, authenticity, selectivity, accuracy and precision of the proposed method with allowable impact on PQ according to UL1741 standard.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Baghaee, H. R., Mirsalim, M., Gharehpetian, G. B., & Talebi, H. A. (2016) · Energy · doi:10.1016/j.energy.2016.09.007 · Cited by 367 · cited 1×
“meta-heuristic optimization algorithms [4], [31]–[35] are widely used in a broad range of applications in nonlinear approximation, prediction, and/or optimization.”
BackgroundSelf-citationData-Mining Model Based Intelligent Differential Microgrid Protection Scheme
Kar, S., Samantaray, S. R., & Zadeh, M. D. (2017) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2380432 · Cited by 295
Lu, X., Yu, X., Lai, J., Guerrero, J. M., & Zhou, H. (2017) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2016.2603844 · Cited by 286
Baghaee, H. R., Mirsalim, M., Gharehpetian, G. B., & Talebi, H. A. (2017) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2677943 · Cited by 219
Self-citationA Fuzzy Rule-Based Approach for Islanding Detection in Distributed Generation
Samantaray, S. R., El-Arroudi, K., Joos, G., & Kamwa, I. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2042625 · Cited by 219
Distributed Noise-Resilient Secondary Voltage and Frequency Control for Islanded Microgrids
Dehkordi, N. M., Baghaee, H. R., Sadati, N., & Guerrero, J. M. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2834951 · Cited by 214
Self-citationA Novel Hybrid Islanding Detection Method for Inverter-Based DGs Using SFS and ROCOF
Khodaparastan, M., Vahedi, H., Khazaeli, F., & Oraee, H. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2406577 · Cited by 205 · cited 3×
“Some of passive methods are based on rate of change of frequency (ROCOF) [24], rate of change of angle difference (ROCPAD), rate of change of independence [25], etc. Active methods inject disturbances into the DN at the PCC and track down response from DN.”
MethodSandia Frequency-Shift Parameter Selection to Eliminate Nondetection Zones
Zeineldin, H. H., & Kennedy, S. (2009) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2008.2005362 · Cited by 161 · cited 7×
“Some of the most popular active methods are high frequency signal injection [26], [28], reactive power, active current disturbance.”
BackgroundInfluentialBaghaee, H. R., Mirsalim, M., & B. Gharehpetian, G. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2581762 · Cited by 159 · cited 4×
“The ANNs have the ability to learn due to flexibility of neuron connection weights, and therefore adapt the solution to improve their performance [1], [5], [16], [36]–[39].”
BackgroundInfluentialSelf-citationGhadimi, N. (2014) · Complexity · doi:10.1002/cplx.21537 · Cited by 153 · cited 1×
“Finally, the proposed islanding detection method is here compared to the previously-reported AI-based methods reported in [40]–[42].”
ResultBaghaee, H. R., Mirsalim, M., & Gharehpetian, G. B. (2016) · Journal of Intelligent & Fuzzy Systems · doi:10.3233/jifs-152372 · Cited by 148 · cited 1×
“meta-heuristic optimization algorithms [4], [31]–[35] are widely used in a broad range of applications in nonlinear approximation, prediction, and/or optimization.”
BackgroundSelf-citationEtemadi, A. H., & Iravani, R. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2229680 · Cited by 148
Baghaee, H. R., Mirsalim, M., Gharehpetian, G. B., & Talebi, H. A. (2017) · IEEE Systems Journal · doi:10.1109/jsyst.2016.2645165 · Cited by 145 · cited 1×
“The ANNs have the ability to learn due to flexibility of neuron connection weights, and therefore adapt the solution to improve their performance [1], [5], [16], [36]–[39].”
BackgroundSelf-citationBaghaee, H. R., Mirsalim, M., Gharehpetian, G. B., & Talebi, H. A. (2017) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2017.04.007 · Cited by 141 · cited 1×
“The performance of DG units and microgrids depends, to an extent, upon the DGs’ operational conditions and the protection systems [14]–[19].”
BackgroundSelf-citationDelghavi, M. B., & Yazdani, A. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2756935 · Cited by 117
Baghaee, H. R., Mirsalim, M., Gharehpetian, G. B., & Talebi, H. A. (2017) · IET Power Electronics · doi:10.1049/iet-pel.2016.0010 · Cited by 112
Self-citationA new artificial neural network based method for islanding detection of distributed generators
Merlin, V. L., dos Santos, R. C., Grilo, A. P., Júnior, J. C. D. M. V., Coury, D. V., & Oleskovicz, M. (2015) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2015.08.016 · Cited by 111 · cited 1×
“Finally, the proposed islanding detection method is here compared to the previously-reported AI-based methods reported in [40]–[42].”
ResultVahedi, H., & KARRARI, M. (2012) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2219628 · Cited by 108 · cited 2×
“New group of detection methods is smart techniques using artificial intelligence (AI) applications including artificial neural network (ANN) [22], ANFIS [24], [25] or fuzzy logic (FL) [30], and some combined with active/passive techniques [23].”
BackgroundMethodBaghaee, H. R., Mirsalim, M., Gharehpetian, G. B., & Talebi, H. A. (2018) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2018.0079 · Cited by 106
Self-citationBaghaee, H. R., Mirsalim, M., Gharehpetian, G. B., & Talebi, H. A. (2016) · Simulation Modelling Practice and Theory · doi:10.1016/j.simpat.2016.12.006 · Cited by 103 · cited 1×
“tion [5]–[8].”
Self-citationBaghaee, H. R., Mirsalim, M., Gharehpetian, G. B., & Talebi, H. A. (2017) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2016.0669 · Cited by 97
Self-citationBaghaee, H. R., Mirsalim, M., Gharehpetian, G. B., & Talebi, H. A. (2017) · IEEE Systems Journal · doi:10.1109/jsyst.2017.2716351 · Cited by 96
Self-citationBaghaee, H. R., Mirsalim, M., Gharehpetian, G. B., & Talebi, H. A. (2017) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2016.1277 · Cited by 94
Self-citationOptimal Sizing of a Stand-alone Wind/Photovoltaic Generation Unit using Particle Swarm Optimization
Kaviani, A. K., Baghaee, H. R., & Riahy, G. H. (2009) · SIMULATION · doi:10.1177/0037549708101181 · Cited by 93 · cited 2×
“meta-heuristic optimization algorithms [4], [31]–[35] are widely used in a broad range of applications in nonlinear approximation, prediction, and/or optimization.”
BackgroundSelf-citationBaghaee, H. R., Mirsalim, M., Gharehpetian, G. B., & Talebi, H. A. (2017) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2017.02.004 · Cited by 91
Self-citationBaghaee, H. R., Mirsalim, M., & Gharehpetian, G. B. (2016) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2016.0315 · Cited by 86
Self-citationVahedi, H., Gharehpetian, G. B., & KARRARI, M. (2012) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2212251 · Cited by 76 · cited 2×
“rate of change of independence [25], etc.”
MethodBaghaee, H. R., Mirsalim, M., Gharehpetian, G. B., & Kaviani, A. K. (2012) · SIMULATION · doi:10.1177/0037549712438715 · Cited by 72
Self-citationBaghaee, H. R., & Abedi, M. (2011) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2010.12.012 · Cited by 51
Self-citationBaghaee, H. R., Mirsalim, M., Gharehpetian, G. B., & Talebi, H. A. (2017) · Journal of Circuits Systems and Computers · doi:10.1142/s0218126617500992 · Cited by 47 · cited 1×
“With rising popularity of DG with involvement of distributed/ renewable energy resources (DERs/RERs), some issues are tied to security and PQ of microgrids [10]–[13].”
BackgroundSelf-citationOptimization of arc models parameter using genetic algorithm
Parizad, A., Baghaee, H. R., Tavakoli, A. R., & Jamali, S. (2009) · International Conference on Electric Power and Energy Conversion Systems · Cited by 44
Self-citationBaghaee, H. R., Mirsalim, M., Gharehpetian, G. B., & Talebi, H. A. (2017) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2017.10.316 · Cited by 43
Self-citationAccurate SFS Parameter Design Criterion for Inverter-Based Distributed Generation
Vahedi, H., KARRARI, M., & Gharehpetian, G. B. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2391193 · Cited by 33 · cited 1×
“tend to optimize it by minimizing NDZs [26], [27].”
BackgroundBignucolo, F., Raciti, A., & Caldon, R. (2014) · Renewable Power Generation Conference (RPG) · doi:10.1049/cp.2014.0824 · Cited by 28 · cited 8×
“tracking and changing particular parameters of network such as voltage [21], reactive power [22], frequency [23], etc.”
BackgroundMethodInfluentialBaghaee, H. R., Mirsalim, M., Sanjari, M. J., & Gharehpetian, G. B. (2008) · International Power Electronics and Motion Control Conference (IPEMC) · doi:10.1109/epepemc.2008.4635357 · Cited by 22 · cited 1×
“The performance of DG units and microgrids depends, to an extent, upon the DGs’ operational conditions and the protection systems [14]–[19].”
BackgroundSelf-citationAdaptive neuro-fuzzy inference system (ANFIS) islanding detection based on wind turbine simulator
Ghadimi, N., & Sobhani, B. (2013) · International Journal of the Physical Sciences · doi:10.5897/ijps2013.3947 · Cited by 15
Islanding Detection in a Distribution System with Modified DG Interface Controller
Subhadra, A. S., Reddy, P. L., & Modi, S. B. (2017) · International Journal of Applied Power Engineering (IJAPE) · doi:10.11591/ijape.v6.i3.pp135-143 · Cited by 14
A Hybrid Multi-feature based Islanding Detection Technique for Grid Connected Distributed Generation
Sareen, K., Bhalja, B. R., & Maheshwari, R. P. (2017) · International Journal of Emerging Electric Power Systems · doi:10.1515/ijeeps-2016-0042 · Cited by 12 · cited 2×
“Communicationbased islanding detection cover the most of the NDZs using communication technologies to confirm DN switch state and islanding, preventing continuation of islanding state [21].”
BackgroundIslanding Detection in a Distribution System with Modified DG Interface Controller
Subhadra, A. S., Reddy, P. L., & Modi, S. B. (2017) · International Journal of Applied Power Engineering (IJAPE) · doi:10.11591/ijape.v6.i3.pp133-141 · Cited by 10 · cited 1×
“Some of the most popular active methods are high frequency signal injection [26], [28], reactive power, active current disturbance.”
Background
Cited by
Support Vector Machine-Based Islanding and Grid Fault Detection in Active Distribution Networks
Baghaee, H. R., Mlakic, D., Nikolovski, S., & Dragicevic, T. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2916621 · Cited by 235
Self-citationA Review on Application of Artificial Intelligence Techniques in Microgrids
Mohammadi, E., Alizadeh, M., Asgarimoghaddam, M., Wang, X., & Simoes, M. G. (2022) · IEEE Journal of Emerging and Selected Topics in Industrial Electronics · doi:10.1109/jestie.2022.3198504 · Cited by 183
“Different AI-based techniques were applied in the literature, such as type-2 FL [43], decision tree-induced fuzzy rule base intelligent protection scheme [44], FL for islanding detection [45], ANNs, and SVMs for fault detection and classification.”
Metadata
- Authors
- Mlakic, D., Baghaee, H. R., & Nikolovski, S.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2019-07
- Volume
- 10
- Issue
- 4
- Pages
- 4411-4424
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2883231199
- Cited by
- 179
- References
- 40
- FWCI
- 7.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).