CoChat

Frequency Derivative-Based Inertia Enhancement by Grid-Connected Power Converters With a Frequency-Locked-Loop

Fang, Jingyang, Zhang, Ruiqi, Li, Hongchang, Tang, Yi · 2019 · IEEE Transactions on Smart Grid
Cited by 170

The DOI matches its Crossref record.

Abstract

Renewable energy sources (RESs) have been extensively employed to replace fossil fuels for reducing carbon footprints. Since RESs are normally coupled to the power grid by fast-response power converters without providing any inertia, the power system inertia generated by synchronous generators continues to decrease, making modern power systems sensitive to frequency events. As a result, undesirable load-shedding, cascading failures, or even large-scale blackouts may occur under severe frequency events. To address the lack of inertia concern, this paper presents a frequency derivative-based inertia enhancement method for battery storage systems. Specifically, the method achieves inertia emulation by proportionally linking the time derivative of the grid frequency and active power references of power converters. The main contribution is to use a frequency-locked-loop to accurately estimate the frequency derivative signal, which avoids the high frequency noises introduced by differential operators. Simulation and experimental results are finally presented to validate the effectiveness of the proposed method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tsg.2018.2871085

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Fang, J., Zhang, R., Li, H., & Tang, Y.
Venue
IEEE Transactions on Smart Grid
Published
2019-09
Volume
10
Issue
5
Pages
4918-4927
ISSN
  • 1949-3053 (ISSN-L)
  • 1949-3061
OpenAlex
W2891023895
Cited by
170
References
0
FWCI
10.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.