FD4C: Automatic Fault Diagnosis Framework for Web Applications in Cloud Computing
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The large-scale dynamic cloud computing environment has raised great challenges for fault diagnosis in Web applications: First, fluctuating workloads cause traditional application models to change over time; second, modeling the behaviors of complex applications usually requires domain knowledge which is difficult to obtain; third, managing large-scale applications manually is impractical for operators. To address these issues, this paper proposes an automatic fault (F) diagnosis (D) framework for (4) Web applications in cloud (C) computing (FD4C). In this paper, we propose an online incremental clustering method to recognize access behavior patterns. We also use correlation analysis to model the correlations between the workloads and application performance/resource utilization metrics in a specific access behavior pattern. FD4C detects faults by discovering the abrupt changes of correlation coefficients with control charts. Then, FD4C identifies the fault-related metrics using a feature selection method. To evaluate our proposal, we inject typical faults into TPC-W benchmark and apply FD4C to diagnose the injected faults. The experimental results show that FD4C can effectively detect the typical faults and accurately locate the metrics related to the faults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detecting large-scale system problems by mining console logs
Xu, W., Huang, L., Fox, A., Patterson, D., & Jordan, M. I. (2009) · Proceedings of the ACM SIGOPS 22nd symposium on Operating systems principles · doi:10.1145/1629575.1629587 · Cited by 1,332 · cited 1×
“In our future work, we will integrate some fine-grained methods, such as tracing request (see [44]) and analyzing logs (see [45]) to locate suspicious sections of source code.”
Method
Cited by
Zhou, X., Peng, X., Xie, T., Sun, J., Ji, C., Liu, D., Xiang, Q., & He, C. (2019) · Proceedings of the 2019 27th ACM Joint Meeting on European Software Engineering Conference and Symposium on the Foundations of Software Engineering · doi:10.1145/3338906.3338961 · Cited by 277
“Wang et al. [52] presented an online approach of incremental clustering for fault localization in web applications.”
BackgroundAn online fault detection model and strategies based on SVM-grid in clouds
Zhang, P., Shu, S., & Zhou, M. (2018) · IEEE/CAA Journal of Automatica Sinica · doi:10.1109/jas.2017.7510817 · Cited by 237
Detecting anomalies in microservices with execution trace comparison
Meng, L., Ji, F., Sun, Y., & Wang, T. (2021) · Future Generation Computer Systems · doi:10.1016/j.future.2020.10.040 · Cited by 70
Self-citationWorkflow-Aware Automatic Fault Diagnosis for Microservice-Based Applications With Statistics
Wang, T., Zhang, W., Xu, J., & Gu, Z. (2020) · IEEE Transactions on Network and Service Management · doi:10.1109/tnsm.2020.3022028 · Cited by 54
Self-citationPanahandeh, M., Hamou-Lhadj, A., Hamdaqa, M., & Miller, J. (2024) · Journal of Systems and Software · doi:10.1016/j.jss.2023.111917 · Cited by 49
Metadata
- Authors
- Wang, T., Zhang, W., Ye, C., Wei, J., Zhong, H., & Huang, T.
- Venue
- IEEE Transactions on Systems, Man, and Cybernetics: Systems
- Published
- 2016-01
- Volume
- 46
- Issue
- 1
- Pages
- 61-75
- ISSN
- 2168-2216 (ISSN-L)
- 2168-2232
- OpenAlex
- W2198041540
- Cited by
- 68
- References
- 1
- FWCI
- 9.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.