Low-Resolution Gait Recognition
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Unlike other biometric authentication methods, gait recognition is noninvasive and effective from a distance. However, the performance of gait recognition will suffer in the low-resolution (LR) case. Furthermore, when gait sequences are projected onto a nonoptimal low-dimensional subspace to reduce the data complexity, the performance of gait recognition will also decline. To deal with these two issues, we propose a new algorithm called superresolution with manifold sampling and backprojection (SRMS), which learns the high-resolution (HR) counterparts of LR test images from a collection of HR/LR training gait image patch pairs. Then, we incorporate SRMS into a new algorithm called multilinear tensor-based learning without tuning parameters (MTP) for LR gait recognition. Our contributions include the following: 1) With manifold sampling, the redundancy of gait image patches is remarkably decreased; thus, the superresolution procedure is more efficient and reasonable. 2) Backprojection guarantees that the learned HR gait images and the corresponding LR gait images can be more consistent. 3) The optimal subspace dimension for dimension reduction is automatically determined without introducing extra parameters. 4) Theoretical analysis of the algorithm shows that MTP converges. Experiments on the USF human gait database and the CASIA gait database show the increased efficiency of the proposed algorithm, compared with previous algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The humanID gait challenge problem: data sets, performance, and analysis
Sarkar, S., Phillips, P. J., Liu, Z., Vega, I. R., Grother, P., & Bowyer, K. W. (2005) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2005.39 · Cited by 1,133 · cited 4×
“1 [24] and the CASIA gait database [32], to evaluate the performance of the proposed SRMTP algorithm.”
BackgroundMethodInfluential
Cited by
Data-Driven Intelligent Transportation Systems: A Survey
Zhang, J., Wang, F.-Y., Wang, K., Lin, W.-H., Xu, X., & Chen, C. (2011) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2011.2158001 · Cited by 1,817
“One way of addressing the cost issue is to enhance the capability of data analysis by designing an effective and reliable classifier for traffic object recognition [41] or to improve the quality of image or video sequences [39], [119].”
BackgroundMethodSelf-citationA survey of multilinear subspace learning for tensor data
Lu, H., Plataniotis, K. N., & Venetsanopoulos, A. N. (2011) · Pattern Recognition · doi:10.1016/j.patcog.2011.01.004 · Cited by 357
Gait Recognition via Effective Global-Local Feature Representation and Local Temporal Aggregation
Lin, B., Zhang, S., & Yu, X. (2021) · 2021 IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv48922.2021.01438 · Cited by 334
Deep Learning-Based Gait Recognition Using Smartphones in the Wild
Zou, Q., Wang, Y., Wang, Q., Zhao, Y., & Li, Q. (2020) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2020.2985628 · Cited by 305
Deep Learning-Based Gait Recognition Using Smartphones in the Wild
Zou, Q., Wang, Y., Wang, Q., Zhao, Y., & Li, Q. (2018) · arXiv · doi:10.48550/arxiv.1811.00338 · Cited by 305
Human Identification Using Temporal Information Preserving Gait Template
Wang, C., Zhang, J., Wang, L., Pu, J., & Yuan, X. (2012) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2011.260 · Cited by 289
Self-citationMulti-Task GANs for View-Specific Feature Learning in Gait Recognition
He, Y., Zhang, J., Shan, H., & Wang, L. (2019) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2018.2844819 · Cited by 245
“However, the performance of gait recognition [1] suffers from various exterior factors including clothing [2], walking speed [3], low resolution [4] and so on.”
BackgroundSelf-citationAccelerometer-Based Gait Recognition by Sparse Representation of Signature Points With Clusters
Zhang, Y., Pan, G., Jia, K., Lu, M., Wang, Y., & Wu, Z. (2015) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2014.2361287 · Cited by 182
“Among gait recognition methods relying on various media, those based on camera vision were intensively researched [13], [14], [15], [16], [17], [18] in the past decade.”
Robust gait recognition: a comprehensive survey
Rida, I., Almaadeed, N., & Almaadeed, S. (2019) · IET Biometrics · doi:10.1049/iet-bmt.2018.5063 · Cited by 119
“Zhang et al. [70] combined super resolution (SR) algorithm with multilinear tensor-based learning without tuning parameters (MTP) to tackle the problem of low resolution GEIs.”
Background
Metadata
- Authors
- Zhang, J., Pu, J., Chen, C., & Fleischer, R.
- Venue
- IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics)
- Published
- 2010-08
- Volume
- 40
- Issue
- 4
- Pages
- 986-996
- ISSN
- 1083-4419 (ISSN-L)
- OpenAlex
- W2139391203
- Cited by
- 84
- References
- 1
- FWCI
- 4.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.