The DOI matches its Crossref record.
A New Gaze-BCI-Driven Control of an Upper Limb Exoskeleton for Rehabilitation in Real-World Tasks
Abstract
This paper proposes a new multimodal architecture for gaze-independent brain-computer interface (BCI)-driven control of a robotic upper limb exoskeleton for stroke rehabilitation to provide active assistance in the execution of reaching tasks in a real setting scenario. At the level of action plan, the patient's intention is decoded by means of an active vision system, through the combination of a Kinect-based vision system, which can online robustly identify and track 3-D objects, and an eye-tracking system for objects selection. At the level of action generation, a BCI is used to control the patient's intention to move his/her own arm, on the basis of brain activity analyzed during motor imagery. The main kinematic parameters of the reaching movement (i.e., speed, acceleration, and jerk) assisted by the robot are modulated by the output of the BCI classifier so that the robot-assisted movement is performed under a continuous control of patient's brain activity. The system was experimentally evaluated in a group of three healthy volunteers and four chronic stroke patients. Experimental results show that all subjects were able to operate the exoskeleton movement by BCI with a classification error rate of 89.4±5.0% in the robot-assisted condition, with no difference of the performance observed in stroke patients compared with healthy subjects. This indicates the high potential of the proposed gaze-BCI-driven robotic assistance for neurorehabilitation of patients with motor impairments after stroke since the earliest phase of recovery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A comprehensive review of EEG-based brain–computer interface paradigms
Abiri, R., Borhani, S., Sellers, E. W., Jiang, Y., & Zhao, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf12e · Cited by 946
Systematic review of Kinect applications in elderly care and stroke rehabilitation
Webster, D., & Celik, O. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-108 · Cited by 436
Upper-Limb Robotic Exoskeletons for Neurorehabilitation: A Review on Control Strategies
Proietti, T., Crocher, V., Roby-Brami, A., & Jarrasse, N. (2016) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2016.2552201 · Cited by 388
Making Sense of Spatio-Temporal Preserving Representations for EEG-Based Human Intention Recognition
Zhang, D., Yao, L., Chen, K., Wang, S., Chang, X., & Liu, Y. (2020) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2019.2905157 · Cited by 365
A survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
Metadata
- Authors
- Frisoli, A., Loconsole, C., Leonardis, D., Banno, F., Barsotti, M., Chisari, C., & Bergamasco, M.
- Venue
- IEEE Transactions on Systems, Man, and Cybernetics, Part C (Applications and Reviews)
- Published
- 2012-11
- Volume
- 42
- Issue
- 6
- Pages
- 1169-1179
- ISSN
- 1094-6977 (ISSN-L)
- 1558-2442
- OpenAlex
- W1966620545
- Cited by
- 217
- References
- 0
- FWCI
- 5.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A New Gaze-BCI-Driven Control of an Upper Limb Exoskeleton for Rehabilitation in Real-World Tasks. https://app.cochat.ai/papers/10.1109/tsmcc.2012.2226444
- The paper
- Frisoli, A., Loconsole, C., Leonardis, D., Banno, F., Barsotti, M., Chisari, C., & Bergamasco, M. (2012). A New Gaze-BCI-Driven Control of an Upper Limb Exoskeleton for Rehabilitation in Real-World Tasks. IEEE Transactions on Systems, Man, and Cybernetics, Part C (Applications and Reviews). https://doi.org/10.1109/tsmcc.2012.2226444
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.