The DOI matches its Crossref record.
Investigating the Impacts of Wind Generation Participation in Interconnection Frequency Response
Abstract
The electrical frequency of an interconnection must be maintained very close to its nominal level at all times. Excessive frequency deviations can lead to load shedding, instability, machine damage, and even blackouts. There is rising concern in the power industry in recent years about the declining amount of inertia and primary frequency response (PFR) in many interconnections. This decline may continue due to increasing penetrations of inverter-coupled generation and the planned retirements of conventional thermal plants. Inverter-coupled variable wind generation is capable of contributing to PFR and inertia; however, wind generation PFR and inertia responses differ from those of conventional generators, and it is not entirely understood how this will affect the system at different wind power penetration levels. The simulation work presented in this paper evaluates the impact of the wind generation provision of these active power control strategies on a large, synchronous interconnection. All simulations were conducted on the U.S. Western Interconnection with different levels of wind power penetration levels. The ability of wind power plants to provide PFRand a combination of synthetic inertial response and PFRsignificantly improved the frequency response performance of the system. The simulation results provide insight to designing and operating wind generation active power controls to facilitate adequate frequency response performance of an interconnection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kroposki, B., Johnson, B., Zhang, Y., Gevorgian, V., Denholm, P., Hodge, B.-M., & Hannegan, B. (2017) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2016.2637122 · Cited by 1,367
Self-citationGrand challenges in the science of wind energy
Veers, P., Dykes, K., Lantz, E., Barth, S., Bottasso, C. L., Carlson, O., Clifton, A., Green, J., Green, P., Holttinen, H., et al. (2019) · Science · doi:10.1126/science.aau2027 · Cited by 1,242
Overgeneration from Solar Energy in California. A Field Guide to the Duck Chart
Denholm, P., O'Connell, M., Brinkman, G., & Jorgenson, J. (2015) · doi:10.2172/1226167 · Cited by 559
The challenges of achieving a 100% renewable electricity system in the United States
Denholm, P., Arent, D. J., Baldwin, S. F., Bilello, D. E., Brinkman, G. L., Cochran, J. M., Cole, W. J., Frew, B., Gevorgian, V., Heeter, J., et al. (2021) · Joule · doi:10.1016/j.joule.2021.03.028 · Cited by 294
Self-citationA review of hydrogen generation, storage, and applications in power system
Ge, L., Zhang, B., Huang, W., Li, Y., Hou, L., Xiao, J., Mao, Z., & Li, X. (2024) · Journal of Energy Storage · doi:10.1016/j.est.2023.109307 · Cited by 281
Metadata
- Authors
- Gevorgian, V., Zhang, Y., & Ela, E.
- Venue
- IEEE Transactions on Sustainable Energy
- Published
- 2015-07
- Volume
- 6
- Issue
- 3
- Pages
- 1004-1012
- ISSN
- 1949-3029 (ISSN-L)
- 1949-3037
- OpenAlex
- W2082662944
- Cited by
- 239
- References
- 0
- FWCI
- 9.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Investigating the Impacts of Wind Generation Participation in Interconnection Frequency Response. https://app.cochat.ai/papers/10.1109/tste.2014.2343836
- The paper
- Gevorgian, V., Zhang, Y., & Ela, E. (2015). Investigating the Impacts of Wind Generation Participation in Interconnection Frequency Response. IEEE Transactions on Sustainable Energy. https://doi.org/10.1109/tste.2014.2343836
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.