The DOI matches its Crossref record.
Optimal Sizing of a Vanadium Redox Battery System for Microgrid Systems
Abstract
The vanadium redox battery (VRB) has proven to be a reliable and highly efficient energy storage system (ESS) for microgrid applications. However, one challenge in designing a microgrid system is specifying the size of the ESS. This selection is made more complex due to the independent power and energy ratings inherent in VRB systems. Sizing a VRB for both required power output and energy storage capacity requires an in-depth analysis to produce both optimal scheduling capabilities and minimum capital costs. This paper presents an analytical method to determine the optimal ratings of VRB energy storage based on an optimal scheduling analysis and cost-benefit analysis for microgrid applications. A dynamic programming (DP) algorithm is used to solve the optimal scheduling problem considering the efficiency and operating characteristics of the VRBs. The proposed method has been applied to determine the optimal VRB power and energy ratings for both isolated and grid-connected microgrids, which contain PV arrays and fossil-fuel-based generation. We first consider the case in which a grid-tie is not available and diesel generation is the backup source of power. The method is then extended to consider the case in which a utility grid tie is available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Battery energy storage system size determination in renewable energy systems: A review
Yang, Y., Bremner, S., Menictas, C., & Kay, M. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.03.047 · Cited by 977
Hannan, M. A., Wali, S. B., Ker, P. J., Rahman, M. S. A., Mansor, M., Ramachandaramurthy, V. K., Muttaqi, K. M., Mahlia, T. M. I., & Dong, Z. Y. (2021) · Journal of Energy Storage · doi:10.1016/j.est.2021.103023 · Cited by 676
Enhancing smart grid with microgrids: Challenges and opportunities
Yoldaş, Y., Önen, A., Muyeen, S. M., Vasilakos, A. V., & Alan, İ. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.01.064 · Cited by 538
Energy Management and Optimization Methods for Grid Energy Storage Systems
Byrne, R. H., Nguyen, T. A., Copp, D. A., Chalamala, B. R., & Gyuk, I. (2018) · IEEE Access · doi:10.1109/access.2017.2741578 · Cited by 406
Self-citationYang, Y., Bremner, S., Menictas, C., & Kay, M. (2022) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2022.112671 · Cited by 325
Metadata
- Authors
- Nguyen, T. A., Crow, M. L., & Elmore, A. C.
- Venue
- IEEE Transactions on Sustainable Energy
- Published
- 2015-07
- Volume
- 6
- Issue
- 3
- Pages
- 729-737
- ISSN
- 1949-3029 (ISSN-L)
- 1949-3037
- OpenAlex
- W2030810955
- Cited by
- 190
- References
- 0
- FWCI
- 16.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal Sizing of a Vanadium Redox Battery System for Microgrid Systems. https://app.cochat.ai/papers/10.1109/tste.2015.2404780
- The paper
- Nguyen, T. A., Crow, M. L., & Elmore, A. C. (2015). Optimal Sizing of a Vanadium Redox Battery System for Microgrid Systems. IEEE Transactions on Sustainable Energy. https://doi.org/10.1109/tste.2015.2404780
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.