Optimized Dispatch of Energy Storage Systems in Unbalanced Distribution Networks
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This paper presents a method to achieve optimal active and reactive power contributions from each energy storage system in an unbalanced distribution network to minimize power loss, while ensuring network current and voltage constraints are satisfied. By modeling loads as either constant current or constant impedance, the ac optimal power flow is transformed into a noniterative convex optimization problem. The application of capacity constraints, voltage constraints, and energy storage constraints in an unbalanced three-phase four-wire system is considered, addressing specific issues pertaining to unbalanced networks such as voltage unbalance and neutral voltage displacement. The proposed method is then used to demonstrate optimized dispatch of energy storage systems in a suitable four-wire unbalanced distribution test network. The contribution of losses in the neutral wire to the total losses is also determined for a test system under a range of operating conditions and various neutral earthing systems, highlighting the importance of considering this in a typical unbalanced distribution network.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Distribution System Modeling and Analysis
Kersting, W. H. (2001) · doi:10.1201/9781420041736 · Cited by 354
Haque, M. M., & Wolfs, P. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.04.025 · Cited by 331
Power flow in four-wire distribution networks—General approach
Ciric, R. M., Feltrin, A. P., & Ochoa, L. F. (2003) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2003.818597 · Cited by 265
Impact of solar photovoltaics on the low-voltage distribution network in New Zealand
Watson, J. D., Watson, N. R., Santos‐Martin, D., Wood, A. R., Lemon, S., & Miller, A. J. V. (2016) · IET Generation, Transmission & Distribution · doi:10.1049/iet-gtd.2014.1076 · Cited by 135 · cited 3×
“Both the reduced powerflow and the full non-linear power flow are implemented in a custom MATLAB solver which was developed and verified against PSS SINCAL and Simscape Power Systems in [15].”
MethodSelf-citationAnalysis of multi-grounded four-wire distribution systems considering the neutral grounding
Chen, T.-H., & Yang, W.-C. (2001) · IEEE Transactions on Power Delivery · doi:10.1109/61.956760 · Cited by 74
Cited by
Yi, Z., Xu, Y., Zhou, J., Wu, W., & Sun, H. (2020) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2020.2980317 · Cited by 204
“2) Thermal and Voltage Constraints: The voltage amplitude and branch power flow should satisfy the security-constrained economic operation [35].”
BackgroundMehrjerdi, H., & Hemmati, R. (2019) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2019.06.195 · Cited by 106
A comprehensive multi-period optimal power flow framework for smart LV networks
Avramidis, I. I., Capitanescu, F., & Deconinck, G. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.3040502 · Cited by 19
Radosavljević, J., Ktena, A., Gajić, M., Milovanović, M., & Živić, J. (2023) · Energies · doi:10.3390/en16114356 · Cited by 10
Metadata
- Authors
- Watson, J. D., Watson, N. R., & Lestas, I.
- Venue
- IEEE Transactions on Sustainable Energy
- Published
- 2018-04
- Volume
- 9
- Issue
- 2
- Pages
- 639-650
- ISSN
- 1949-3029 (ISSN-L)
- 1949-3037
- OpenAlex
- W2756166591
- Cited by
- 66
- References
- 5
- FWCI
- 3.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimized Dispatch of Energy Storage Systems in Unbalanced Distribution Networks. https://app.cochat.ai/papers/10.1109/tste.2017.2752964
- The paper
- Watson, J. D., Watson, N. R., & Lestas, I. (2018). Optimized Dispatch of Energy Storage Systems in Unbalanced Distribution Networks. IEEE Transactions on Sustainable Energy. https://doi.org/10.1109/tste.2017.2752964
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.