Robust Capacity Assessment of Distributed Generation in Unbalanced Distribution Networks Incorporating ANM Techniques
Open accessThe DOI matches its Crossref record.
Abstract
To settle a large-scale integration of renewable distributed generations (DGs), it requires to assess the maximal DG hosting capacity of active distribution networks (ADNs). For fully exploiting the ability of ADNs to accommodate DG, this paper proposes a robust comprehensive DG capacity assessment method considering three-phase power flow modelling and active network management (ANM) techniques. The two-stage adjustable robust optimization is employed to tackle the uncertainties of load demands and DG outputs. With our method, system planners can obtain the maximum penetration level of DGs with their optimal sizing and sitting decisions. Meanwhile, the robust optimal ANM schemes can be generated for each operation time period, including network reconfiguration, on-load-tap-changers regulation, and reactive power compensation. In addition, a three-step optimization algorithm is proposed to enhance the accuracy of DG capacity assessment results. The optimality and robustness of our method are validated via numerical tests on an unbalanced IEEE 33-bus distribution system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Despite their extensive applications, the accuracy of such models can vary, particularly outside near-nominal operating regions, as indicated in [16], [26].”
From Optimizing Parameters of the LinDistFlow Power Flow Approximation for Distribution Systems (2026) · cites this paper as [26]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Leveraging Two-Stage Adaptive Robust Optimization for Power Flexibility Aggregation
Chen, X., & Li, N. (2021) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2021.3068341 · Cited by 168
Self-citationA Review of the Tools and Methods for Distribution Networks’ Hosting Capacity Calculation
Zain ul Abideen, M., Ellabban, O., & Al-Fagih, L. (2020) · Energies · doi:10.3390/en13112758 · Cited by 161
Yang, T., Guo, Y., Deng, L., Sun, H., & Wu, W. (2021) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2020.3039984 · Cited by 114
Self-citationUmoh, V., Davidson, I., Adebiyi, A., & Ekpe, U. (2023) · Energies · doi:10.3390/en16083609 · Cited by 71
Yao, H., Qin, W., Jing, X., Zhu, Z., Wang, K., Han, X., & Wang, P. (2022) · Applied Energy · doi:10.1016/j.apenergy.2022.119681 · Cited by 33
Parameterized Linear Power Flow for High Fidelity Voltage Solutions in Distribution Systems
Marković, M., & Hodge, B.-M. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3218263 · Cited by 26
Optimizing Parameters of the LinDistFlow Power Flow Approximation for Distribution Systems
Taheri, B., Gupta, R. K., & Molzahn, D. K. (2026) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2025.3630047 · Cited by 24
A comprehensive multi-period optimal power flow framework for smart LV networks
Avramidis, I. I., Capitanescu, F., & Deconinck, G. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.3040502 · Cited by 19
Wang, X., & Chen, X. (2026) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2026.3684791
Self-citation
Metadata
- Authors
- Chen, X., Wu, W., & Zhang, B.
- Venue
- IEEE Transactions on Sustainable Energy
- Published
- 2018-04
- Volume
- 9
- Issue
- 2
- Pages
- 651-663
- ISSN
- 1949-3029 (ISSN-L)
- 1949-3037
- OpenAlex
- W2963046056
- Cited by
- 141
- References
- 0
- FWCI
- 3.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.