Shipboard Microgrids: A Novel Approach to Load Frequency Control
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Due to the fast development of renewable energy systems and the severe limitations enforced by the marine pollution protocol, the utilizing of wind turbines (WTs), solar generation, sea wave energy (SWE), and energy storage systems (ESS) in marine vessel power systems have been attracting a lot of attention. Hence, a marine vessel power system with photovoltaic, WT, SWE, and ESS can be considered as a specific mobile islanded microgrid. Consequently, the main target of this paper is to design a new optimal fractional order fuzzy PD+I load frequency controller (LFC) for islanded microgrids in a ship power system. Since the performance of the controller depends on its parameters, the optimization of these coefficients can play a significant role in improving the output performance of the LFC control. Accordingly, a modified black hole optimization algorithm is utilized for the adaptive tuning of the coefficients of noninteger fuzzy PD+I controller. The performance of the shipboard microgrid is evaluated by utilizing real-world wind power fluctuation and solar radiation data. Finally, the extensive studies and hardware-in-the-loop simulations are applied to prove that the proposed controller can track the reference frequency with lower deviation as well as it is more robust in comparison with the prior-art controllers utilized in the case studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Black hole: A new heuristic optimization approach for data clustering
Hatamlou, A. (2013) · Information Sciences · doi:10.1016/j.ins.2012.08.023 · Cited by 1,370 · cited 2×
“The movement characteristic of the stars can be expressed as [36], [37]:”
BackgroundIntelligent Frequency Control in an AC Microgrid: Online PSO-Based Fuzzy Tuning Approach
Bevrani, H., Habibi, F., Babahajyani, P., Watanabe, M., & Mitani, Y. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2196806 · Cited by 599
Optimal sizing of hybrid PV/diesel/battery in ship power system
Lan, H., Wen, S., Hong, Y.-Y., Yu, D. C., & Zhang, L. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.08.031 · Cited by 413 · cited 1×
“1 represents an isolated Shipboard MG in which DGs such as PVs, SWEs, WTs and energy storage units like Battery Energy Storage System (BESS) and Flywheel Energy Storage System (FESS) supply the distributed loads [25].”
BackgroundJin, Z., Sulligoi, G., Cuzner, R., Meng, L., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Electrification Magazine · doi:10.1109/mele.2016.2544203 · Cited by 333 · cited 2×
“Accordingly, a wide range of researches [3]–[7] have been achieved concerning the utilization of the islanded MG in the marine vessel.”
BackgroundRobust Frequency Control in an Islanded Microgrid: H∞ and μ-Synthesis Approaches
Bevrani, H., Feizi, M. R., & Ataee, S. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2446984 · Cited by 317 · cited 3×
“In [14], the application of robust H-infinity control in the LFC of an isolated MG is studied.”
MethodBevrani, H., & Shokoohi, S. (2013) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2258947 · Cited by 292
A new load frequency control strategy for micro-grids with considering electrical vehicles
Khooban, M. H., Niknam, T., Blaabjerg, F., & Dragičević, T. (2017) · Electric Power Systems Research · doi:10.1016/j.epsr.2016.10.057 · Cited by 252 · cited 3×
“In order to improve the response of the LFC, many controllers including conventional Proportional–Integral– Derivative (PID) control [8], intelligent control [9], adaptive control [10], robust control [11] and Model Predictive Control (MPC) [12] have been applied to the Distributed Generations (DGs) of islanded MGs.”
BackgroundMethodSelf-citationFuzzy Logic-Based Load-Frequency Control Concerning High Penetration of Wind Turbines
Bevrani, H., & Daneshmand, P. R. (2012) · IEEE Systems Journal · doi:10.1109/jsyst.2011.2163028 · Cited by 251 · cited 1×
“Moreover, the reader can refer to [17]–[21] to study more about the LFC and the importance of the LFC in modern power systems.”
BackgroundMaleki, A., & Askarzadeh, A. (2014) · Solar Energy · doi:10.1016/j.solener.2014.05.016 · Cited by 213
A robust adaptive load frequency control for micro-grids
Khooban, M. H., Niknam, T., Blaabjerg, F., Davari, P., & Dragičević, T. (2016) · ISA Transactions · doi:10.1016/j.isatra.2016.07.002 · Cited by 199
Self-citation
Cited by
Fang, S., Wang, Y., Gou, B., & Xu, Y. (2020) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2019.2950538 · Cited by 328
“In [85], the concept of load frequency control is introduced to overcome the PV and wind fluctuations.”
BackgroundLu, K., Zhou, W., Zeng, G., & Zheng, Y. (2019) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2018.08.043 · Cited by 189
Latif, A., Hussain, S. M. S., Das, D. C., & Ustun, T. S. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.114858 · Cited by 183
Metadata
- Authors
- Khooban, M.-H., Dragicevic, T., Blaabjerg, F., & Delimar, M.
- Venue
- IEEE Transactions on Sustainable Energy
- Published
- 2018-04
- Volume
- 9
- Issue
- 2
- Pages
- 843-852
- ISSN
- 1949-3029 (ISSN-L)
- 1949-3037
- OpenAlex
- W2765682349
- Cited by
- 220
- References
- 21
- FWCI
- 12.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Shipboard Microgrids: A Novel Approach to Load Frequency Control. https://app.cochat.ai/papers/10.1109/tste.2017.2763605
- The paper
- Khooban, M.-H., Dragicevic, T., Blaabjerg, F., & Delimar, M. (2018). Shipboard Microgrids: A Novel Approach to Load Frequency Control. IEEE Transactions on Sustainable Energy. https://doi.org/10.1109/tste.2017.2763605
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.