Condition Monitoring of Wind Turbine Generators Using SCADA Data Analysis
Abstract
Utility-scale wind turbines are equipped with a supervisory control and data acquisition (SCADA) system for remote supervision and control. The SCADA system accumulates a large amount of data that contains the health conditions of the wind turbines. Thus, it is interesting to mine the health status-related information from SCADA data for wind turbine condition monitoring. In this article, an ensemble approach is proposed to detect anomalies and diagnose faults in wind turbines. Historical SCADA data collected from healthy wind turbines are used to model their normal behaviors and build a Mahalanobis space as a reference space. By comparing the predicted behavior of the wind turbine by a trained model with the reference space, anomalies can be detected. Finally, wind turbine faults are diagnosed through the analysis of the distributions and correlations of their SCADA data. The proposed approach is validated by using the SCADA data collected from two field wind turbines. Results show that it can detect anomalies and diagnose the corresponding failure components before the wind turbines have to be shut down for maintenance.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
SCADA systems are only minimally present in the wind turbine industry, and they are not acquiring data from the blades but rather from static parts.
“However, they are only minimally present in the wind turbine industry, and they are not acquiring data from the blades but rather from statics parts [5].”
From Aerosense: A Self-Sustainable and Long-Range Bluetooth Wireless Sensor Node for Aerodynamic and Aeroacoustic Monitoring on Wind Turbines (2023) · cites this paper as [5]
Acquiring aerodynamic and aeroacoustic data from the blades of a hundreds meters' tall turbine usually implies considerable effort and cost in measurement campaigns.
“In practice, this usually implies considerable effort and cost in measurement campaigns [5], [6].”
From Aerosense: A Self-Sustainable and Long-Range Bluetooth Wireless Sensor Node for Aerodynamic and Aeroacoustic Monitoring on Wind Turbines (2023) · cites this paper as [5]
Cites
Chen, M., Mao, S., & Liu, Y. (2014) · Mobile Networks and Applications · doi:10.1007/s11036-013-0489-0 · Cited by 2,913 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Polonelli, T., Muller, H., Kong, W., Fischer, R., Benini, L., & Magno, M. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3224307 · Cited by 35 · see citing works
- Authors
- Jin, X., Xu, Z., & Qiao, W.
- Affiliations
- Zhejiang University of Technology (CN)
- University of Nebraska–Lincoln (US)
- Venue
- IEEE Transactions on Sustainable Energy
- Published
- 2021-01
- Volume
- 12
- Issue
- 1
- Pages
- 202-210
- ISSN
- 1949-3029 (ISSN-L)
- 1949-3037
- OpenAlex
- W3017705806
- Cited by
- 209
- References
- 1
- Citations by year
- 2026: 22 · 2025: 36 · 2024: 45 · 2023: 45 · 2022: 34 · 2021: 22 · 2020: 5
- FWCI
- 13.11
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Sustainable Energy (publishedVersion)
- Funders
- National Natural Science Foundation of China (51505424)
- Zhejiang Provincial Natural Science Foundation of China (LY15E050019)
- Natural Science Foundation of Ningbo (2018A610045)
- Zhejiang University of Technology
- Ministry of Education & Zhejiang Province (EM2019120104)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wind Turbine Control Systems
- Keywords
- wind turbine condition monitoring, SCADA data, anomaly detection, fault diagnosis, ensemble learning, Mahalanobis distance, reference space, predictive maintenance, wind turbine generator
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review