Optimal Operation of Energy Hubs With Large-Scale Distributed Energy Resources for Distribution Network Congestion Management
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Congestion problems might occur in distribution networks as the penetration of distributed energy resources (DERs) progresses. This study focuses on the complementarity of multiple energy resources in energy hubs (EHs) to solve possible distribution network congestions. First, we consider an EH in which combined cooling, heating and power (CCHP) units and heat pumps are integrated with renewable energy resources. The EH models the intrinsic coupling relationship among various energy carriers, forming a flexible operation where electricity, natural gas, cooling and heat can complement each other. Next, an optimal operation strategy of multiple energy hubs enables gas-to-electricity to provide local energy supply for EH during electricity peak periods, and consume renewable energy generation by the complementarity of electricity, heat and cooling. In addition, the uncertainty of renewable energy resources is taken into account via scenario-based stochastic programming. Numerical results show that the proposed operation strategy explores EHs' operation flexibility to mitigate distribution network congestion when we consider high renewable energy penetration in power systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Branch Flow Model: Relaxations and Convexification—Part I
Farivar, M., & Low, S. H. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2255317 · Cited by 1,541 · cited 2×
“It is proved that (40) will be active at the optimal solution [33], thus the relaxation is exact.”
BackgroundMethodCoordinated charging of electric vehicles for congestion prevention in the distribution grid
Hu, J., You, S., Lind, M., & Ostergaard, J. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2279007 · Cited by 330 · cited 1×
“3064375 RES generation peak and load demand peak could occur at different periods [3], [4].”
BackgroundSelf-citationVerzijlbergh, R. A., De Vries, L. J., & Lukszo, Z. (2014) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2300941 · Cited by 210 · cited 1×
“However, the method might fail in some real applications because the variable renewable generation weakens the correlation between price signals and demands [12].”
Method
Cited by
Rahman, A., Farrok, O., & Haque, M. M. (2022) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2022.112279 · Cited by 1,105
Metadata
- Authors
- Hu, J., Liu, X., Shahidehpour, M., & Xia, S.
- Venue
- IEEE Transactions on Sustainable Energy
- Published
- 2021-07
- Volume
- 12
- Issue
- 3
- Pages
- 1755-1765
- ISSN
- 1949-3029 (ISSN-L)
- 1949-3037
- OpenAlex
- W3133762782
- Cited by
- 240
- References
- 3
- FWCI
- 11.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal Operation of Energy Hubs With Large-Scale Distributed Energy Resources for Distribution Network Congestion Management. https://app.cochat.ai/papers/10.1109/tste.2021.3064375
- The paper
- Hu, J., Liu, X., Shahidehpour, M., & Xia, S. (2021). Optimal Operation of Energy Hubs With Large-Scale Distributed Energy Resources for Distribution Network Congestion Management. IEEE Transactions on Sustainable Energy. https://doi.org/10.1109/tste.2021.3064375
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.