Grid-Forming Control for Solar PV Systems With Power Reserves
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper presents a grid-forming control (GFC) scheme for two-stage photovoltaic (PV) systems that maintains power reserves by operating below the maximum power point (MPP). The PV plant in GFC mode behaves like a voltage source that supports the grid during disturbances in full or limited grid-forming mode as per the reserve availability. This is a model-free method that avoids the estimation of MPP power in real-time commonly done in the literature, which makes it simpler and more reliable. The proposed control also features an enhanced current limitation scheme that guarantees containment of the current overshoots during faults, which is not trivial in voltage-sourced GFC inverters. A thorough investigation is done, exploring various generation mixtures of synchronous machines (SM), GFC and grid-following (GFL) inverters, and all common disturbances, e.g., load change, faults and irradiance transients. The results show very favorable dynamic performance by the GFC inverters, far superior to GFL inverters and directly comparable to SMs. It is found that replacing SMs with GFC inverters may improve the frequency profile and terminal voltage during disturbances, despite losing out in the mechanical inertia and the strict inverter overcurrent limits.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comparison of Photovoltaic Array Maximum Power Point Tracking Techniques
Esram, T., & Chapman, P. L. (2007) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.874230 · Cited by 5,425
Frequency Stability of Synchronous Machines and Grid-Forming Power Converters
Tayyebi, A., Gross, D., Anta, A., Kupzog, F., & Dorfler, F. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2966524 · Cited by 442 · cited 5×
“RoCoF Rate of change of frequency SM Synchronous machine UPS Uninterruptible power source VOC Virtual oscillator-based control VSC Voltage source converter VSM Virtual synchronous machine I. INTRODUCTION OWER system stability concerns are growing with the increasing share of renewable energy sources (RESs) [1], especi…”
Influential
Cited by
Overcurrent Limiting in Grid-Forming Inverters: A Comprehensive Review and Discussion
Baeckeland, N., Chatterjee, D., Lu, M., Johnson, B., & Seo, G.-S. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3430316 · Cited by 271
He, L., & Yu, S. (2024) · IEEE Open Access Journal of Power and Energy · doi:10.1109/oajpe.2024.3360854 · Cited by 15
“Although these control methods exhibit distinct dynamic performances owing to their unique characteristics, they share a common-ality in regulating inverter output with a similar steady-state response, as they all adhere to the droop law [29].”
Background
Metadata
- Authors
- Pawar, B., Batzelis, E., Chakrabarti, S., & Pal, B.
- Venue
- IEEE Transactions on Sustainable Energy
- Published
- 2021-10
- Volume
- 12
- Issue
- 4
- Pages
- 1947-1959
- ISSN
- 1949-3029 (ISSN-L)
- 1949-3037
- OpenAlex
- W3155743176
- Cited by
- 197
- References
- 2
- FWCI
- 12.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Grid-Forming Control for Solar PV Systems With Power Reserves. https://app.cochat.ai/papers/10.1109/tste.2021.3074066
- The paper
- Pawar, B., Batzelis, E., Chakrabarti, S., & Pal, B. (2021). Grid-Forming Control for Solar PV Systems With Power Reserves. IEEE Transactions on Sustainable Energy. https://doi.org/10.1109/tste.2021.3074066
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.