The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Short-lag spatial coherence of backscattered echoes: imaging characteristics
Open accessAbstract
Conventional ultrasound images are formed by delay-and-sum beamforming of the backscattered echoes received by individual elements of the transducer aperture. Although the delay-and-sum beamformer is well suited for ultrasound image formation, it is corrupted by speckle noise and challenged by acoustic clutter and phase aberration. We propose an alternative method of imaging utilizing the short-lag spatial coherence (SLSC) of the backscattered echoes. Compared with matched B-mode images, SLSC images demonstrate superior SNR and contrast-to-noise ratio in simulated and experimental speckle-generating phantom targets, but are shown to be challenged by limited point target conspicuity. Matched B-mode and SLSC images of a human thyroid are presented. The challenges and opportunities of real-time implementation of SLSC imaging are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boone, K. G., & Holder, D. S. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02520003 · Cited by 1,919
Acoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility
Nightingale, K., Soo, M. S., Nightingale, R., & Trahey, G. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00499-9 · Cited by 1,108
Self-citationCamacho, J., Parrilla, M., & Fritsch, C. (2009) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1128 · Cited by 525
Adaptive imaging using the generalized coherence factor
Li, P.-C., & Li, M.-L. (2003) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2003.1182117 · Cited by 514
Coherence factor of speckle from a multi-row probe
Hollman, K. W., Rigby, K. W., & O'Donnell, M. (2003) · 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027) · doi:10.1109/ultsym.1999.849225 · Cited by 276
Clutter filter design for ultrasound color flow imaging
Bjaerum, S., Torp, H., & Kristoffersen, K. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.985705 · Cited by 257
Time-delay- and time-reversal-based robust capon beamformers for ultrasound imaging
Wang, Z., Li, J., & Wu, R. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.857222 · Cited by 196
Axial resolution in elastography
Righetti, R., Ophir, J., & Ktonas, P. Y. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00495-1 · Cited by 127
Dahl, J., Dumont, D. M., Allen, J. D., Miller, E. M., & Trahey, G. E. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.11.001 · Cited by 107
Self-citationTrade-offs between the axial resolution and the signal-to-noise ratio in elastography
Srinivasan, S. S., Righetti, R., & Ophir, J. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(03)00037-1 · Cited by 81
Cited by
A survey on deep learning in medical ultrasound imaging
Song, K., Feng, J., & Chen, D. (2024) · Frontiers in Physics · doi:10.3389/fphy.2024.1398393 · Cited by 59
Metadata
- Authors
- Lediju, M. A., Trahey, G. E., Byram, B. C., & Dahl, J. J.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 2011-07
- Volume
- 58
- Issue
- 7
- Pages
- 1377-1388
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2166591710
- Cited by
- 445
- References
- 11
- FWCI
- 11.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Short-lag spatial coherence of backscattered echoes: imaging characteristics. https://app.cochat.ai/papers/10.1109/tuffc.2011.1957
- The paper
- Lediju, M. A., Trahey, G. E., Byram, B. C., & Dahl, J. J. (2011). Short-lag spatial coherence of backscattered echoes: imaging characteristics. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. https://doi.org/10.1109/tuffc.2011.1957
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.