Abstract
Focused ultrasound (FUS) has been shown promise in treating the brain locally and noninvasively. Transcranial passive cavitation detection (PCD) provides methodology for monitoring the treatment in real time, but the skull effects remain a major challenge for its translation to the clinic. In this study, we investigated the sensitivity, reliability, and limitations of PCD through primate (macaque and human) skulls in vitro. The results were further correlated with the in vivo macaque studies including the transcranial PCD calibration and real-time monitoring of blood-brain barrier (BBB) opening, with magnetic resonance imaging assessing the opening and safety. The stable cavitation doses using harmonics (SCDh) and ultraharmonics (SCDu), the inertial cavitation dose (ICD), and the cavitation SNR were quantified based on the PCD signals. Results showed that through the macaque skull, the pressure threshold for detecting the SCDh remained the same as without the skull in place, whereas it increased for the SCDu and ICD; through the human skull, it increased for all cavitation doses. The transcranial PCD was found to be reliable both in vitro and in vivo when the transcranial cavitation SNR exceeded the 1-dB detection limit through the in vitro macaque (attenuation: 4.92 dB/mm) and human (attenuation: 7.33 dB/ mm) skull. In addition, using long pulses enabled reliable PCD monitoring and facilitate BBB opening at low pressures. The in vivo results showed that the SCDh became detectable at pressures as low as 100 kPa; the ICD became detectable at 250 kPa, although it could occur at lower pressures; and the SCDu became detectable at 700 kPa and was less reliable at lower pressures. Real-time monitoring of PCD was further implemented during BBB opening, with successful and safe opening achieved at 250 to 600 kPa in both the thalamus and the putamen. In conclusion, this study shows that transcranial PCD in macaques in vitro and in vivo, and in humans in vitro, is reliable by improving the cavitation SNR beyond the 1-dB detection limit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tung, Y.-S., Marquet, F., Teichert, T., Ferrera, V., & Konofagou, E. E. (2011) · Applied Physics Letters · doi:10.1063/1.3580763 · Cited by 119 · cited 4×
“This study provides critical information for single-element Pcd [1], [24], [25] and passive acoustic mapping [26]–[28] in both preclinical and clinical applications.”
BackgroundMethodSelf-citation
Cited by
Scanning ultrasound removes amyloid-β and restores memory in an Alzheimer’s disease mouse model
Leinenga, G., & Götz, J. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa2512 · Cited by 498
“This could be facilitated by the recent development of advanced methods, such as passive cavitation detection, which is currently being evaluated in both rodents and primates (29).”
MethodFocused ultrasound-mediated drug delivery through the blood–brain barrier
Burgess, A., Shah, K., Hough, O., & Hynynen, K. (2015) · Expert Review of Neurotherapeutics · doi:10.1586/14737175.2015.1028369 · Cited by 323
Ultrasound treatment of neurological diseases — current and emerging applications
Leinenga, G., Langton, C., Nisbet, R., & Götz, J. (2016) · Nature Reviews Neurology · doi:10.1038/nrneurol.2016.13 · Cited by 275
Downs, M. E., Buch, A., Sierra, C., Karakatsani, M. E., Chen, S., Konofagou, E. E., & Ferrera, V. P. (2015) · PLOS ONE · doi:10.1371/journal.pone.0125911 · Cited by 220
“An initial six-second sonication without MB was used as a control for real time cavitation monitoring [31].”
MethodSelf-citationWang, J., Li, Z., Pan, M., Fiaz, M., Hao, Y., Yan, Y., Sun, L., & Yan, F. (2022) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2022.114539 · Cited by 161
Metadata
- Authors
- Wu, S.-Y., Tung, Y.-S., Marquet, F., Downs, M. E., Sanchez, C. S., Chen, C. C., Ferrera, V., & Konofagou, E.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Published
- 2014-06
- Volume
- 61
- Issue
- 6
- Pages
- 966-978
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2131875975
- Cited by
- 102
- References
- 1
- FWCI
- 4.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.