The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Evolution of ultrasound beamformers
Abstract
Real-time ultrasonic imaging systems have been available for more than thirty years. During this time much has occurred to the basic architecture and functions of these clinical systems and their beamformers, which are, in many ways, the most important components of these systems. This talk will review some of the changes that have occurred and will discuss current trends in beamformer design. Throughout most of the 30 years of real time imaging, analog beamformers have been the mainstay of all instruments. The common methods for the implementation of analog beamformers for annular, linear/curved arrays, and phased arrays will be reviewed and the distinguishing characteristics identified. At the present time the industry is undergoing a major shift toward digital beamformation with the introduction of several commercial systems. Given that the earliest digital systems were available roughly 15 years ago, it is fair to say that the introduction of digital beamformers has been relatively slow. Today this shift seems to be gaining momentum. Some of the factors causing these shifts will be reviewed along the the common types of designs and implementations. The ongoing search for improved imaging performance will continue to introduce new challenges for beamformer designers. Among already proposed imaging methods and techniques are elevation focusing (1.5D arrays), synthetic apertures, 2D and sparse arrays, phase aberration correction, and others. The most common complication introduced by these is a significant increase in channel count. Further, there will also be beamformer design issues related to signal processing. These include not only Doppler processing but also the processing of signals due to novel contrast agents. Finally, with advances in computer and microelectronics technologies, the way we view beamformation may have to undergo sizeable changes. These topics will be reviewed not only as technical challenges but also in light of the constraints introduced by today's marketplace.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synthetic aperture imaging for small scale systems
Karaman, M., Li, P.-C., & O'Donnell, M. (1995) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.384453 · Cited by 575
Lu, J.-Y., & Greenleaf, J. F. (1992) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.166806 · Cited by 511
Digital signal processing for sonar
Knight, W. C., Pridham, R. G., & Kay, S. M. (1981) · Proceedings of the IEEE · doi:10.1109/proc.1981.12186 · Cited by 410
A comparison of efficient beamforming algorithms
Mucci, R. (1984) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1984.1164359 · Cited by 205
Two-Dimensional Arrays for Medical Ultrasound
Smith, S. W., Trahey, G. E., & von Ramm, O. T. (1992) · Ultrasonic Imaging · doi:10.1177/016173469201400301 · Cited by 157
Digital beamforming in ultrasound
Steinberg, B. D. (1992) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.165556 · Cited by 148
Pipelined Sampled-Delay Focusing in Ultrasound Imaging Systems
Kim, J. H., Song, T. K., & Park, S. B. (1987) · Ultrasonic Imaging · doi:10.1177/016173468700900201 · Cited by 58
A New Digital Phased Array System for Dynamic Focusing and Steering with Reduced Sampling Rate
Song, T., & Park, S. B. (1990) · Ultrasonic Imaging · doi:10.1177/016173469001200101 · Cited by 53
Synthetic focus imaging using partial datasets
Cooley, & Робинсон (1994) · doi:10.1109/ultsym.1994.401884 · Cited by 48
VLSI circuits for adaptive digital beamforming in ultrasound imaging
Karaman, M., Atalar, A., & Köymen, H. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.251122 · Cited by 41
Cited by
A synthetic time-reversal imaging method for structural health monitoring
Wang, C. H., Rose, J. T., & Chang, F.-K. (2004) · Smart Materials and Structures · doi:10.1088/0964-1726/13/2/020 · Cited by 545
Two-dimensional temperature estimation using diagnostic ultrasound
Simon, C., VanBaren, P., & Ebbini, E. S. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.710592 · Cited by 433
Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays
Wang, C., Qi, B., Lin, M., Zhang, Z., Makihata, M., Liu, B., Zhou, S., Huang, Y.-H., Hu, H., Gu, Y., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00763-4 · Cited by 274
A survey on deep learning in medical ultrasound imaging
Song, K., Feng, J., & Chen, D. (2024) · Frontiers in Physics · doi:10.3389/fphy.2024.1398393 · Cited by 59
Metadata
- Authors
- Thomenius, K. E.
- Venue
- 1996 IEEE Ultrasonics Symposium. Proceedings
- Publisher
- IEEE
- Published
- 2002-12-24
- Volume
- 2
- Pages
- 1615-1622
- ISSN
- 1051-0117 (ISSN-L)
- OpenAlex
- W2158793892
- Cited by
- 325
- References
- 11
- FWCI
- 40.12
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evolution of ultrasound beamformers. https://app.cochat.ai/papers/10.1109/ultsym.1996.584398
- The paper
- Thomenius, K. E. (2002). Evolution of ultrasound beamformers. 1996 IEEE Ultrasonics Symposium. Proceedings. https://doi.org/10.1109/ultsym.1996.584398
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.