Coherence factor of speckle from a multi-row probe
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The coherence factor provides a quantitative measure of image quality. It is defined as the ratio of the coherent sum across array elements to the incoherent sum and measures the distribution of ultrasonic energy between the main beam and side lobes of a radiation pattern. Values range from 0 to 1. For low values most of the energy is outside of the main beam, and for high values it is in the main beam. The authors have applied the van Cittert-Zernike theorem to determine analytic solutions of the coherence factor for single and multi-row arrays. The solution depends only on the number of rows and columns in a transducer array. With a multi-row probe, the authors imaged a uniform tissue-mimicking phantom and saved coherent signals. Images of the phantom were produced based on coherent and incoherent summations of array elements. They then combined the two images to produce a coherence factor image. Within the focal region, average coherence was 0.50 for the phantom which compares favorably to a value of 0.53 from the analytic solution. Next, phase distortions of pi/2 and pi radians were electronically introduced at specific elements, and the phantom was imaged again. Phase distortion greatly effects energy distribution for coherent summations but has a minimal effect on incoherent summations. An introduced distortion of pi/2 decreased the average coherence factor to 0.33. A distortion of pi further decreased it to 0.11. Results of human studies showed decreased average coherence factors compared to undistorted phantom images. These results suggest that the coherence factor provides a quantitative measure of beam quality for in vivo imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Time reversal of ultrasonic fields. I. Basic principles
Fink, M. (1992) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.156174 · Cited by 1,525
Phase aberration correction in medical ultrasound using speckle brightness as a quality factor
Nock, L., Trahey, G. E., & Smith, S. W. (1989) · The Journal of the Acoustical Society of America · doi:10.1121/1.397889 · Cited by 331
Cited by
Camacho, J., Parrilla, M., & Fritsch, C. (2009) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1128 · Cited by 525
Adaptive imaging using the generalized coherence factor
Li, P.-C., & Li, M.-L. (2003) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2003.1182117 · Cited by 514
Short-lag spatial coherence of backscattered echoes: imaging characteristics
Lediju, M. A., Trahey, G. E., Byram, B. C., & Dahl, J. J. (2011) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2011.1957 · Cited by 445
Deep Neural Networks for Ultrasound Beamforming
Luchies, A. C., & Byram, B. C. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2809641 · Cited by 182
A survey on deep learning in medical ultrasound imaging
Song, K., Feng, J., & Chen, D. (2024) · Frontiers in Physics · doi:10.3389/fphy.2024.1398393 · Cited by 59
Metadata
- Authors
- Hollman, K. W., Rigby, K. W., & O'Donnell, M.
- Venue
- 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027)
- Publisher
- IEEE
- Published
- 2003-01-22
- Volume
- 2
- Pages
- 1257-1260
- ISSN
- 1948-5719 (ISSN-L)
- OpenAlex
- W2119026190
- Cited by
- 276
- References
- 2
- FWCI
- 5.93
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.