A survey of perceptual feedback issues in dexterous telemanipulation. I. Finger force feedback
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Some specific requirements on the design of dexterous master devices meant for teleoperating multifingered robotic hands, within the context of finger force feedback, are identified and analyzed. The requirements are of two categories, i.e., constructional and functional. The constructional issues consist of the isomorphism, portability, motion range capability, and accommodation for human hand size variability. The functional issues consist of bandwidth compatibility with the human hand (which itself has asymmetric input/output characteristics), proprioceptive (force limit) compatibility, and consideration of the psychometric stability of the human hand in sensing force magnitudes and variations. Also of importance is the sensitivity of the master device that must be more than that of the human hand. In this regard, 14 existing designs of hand masters are evaluated to see how well they satisfy the stated constructional and functional requirements.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hand movements: A window into haptic object recognition
Lederman, S. J., & Klatzky, R. L. (1987) · Cognitive Psychology · doi:10.1016/0010-0285(87)90008-9 · Cited by 2,016
Cited by
Toward Haptic Communications Over the 5G Tactile Internet
Antonakoglou, K., Xu, X., Steinbach, E., Mahmoodi, T., & Dohler, M. (2018) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2018.2851452 · Cited by 250
MRI/fMRI-compatible robotic system with force feedback for interaction with human motion
Gassert, R., Moser, R., Burdet, E., & Bleuler, H. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871897 · Cited by 188
“Further, the devices should produce smooth movements as haptic senses are sensitive to high-frequency vibrations [2], [25].”
Control of prosthetic hands via the peripheral nervous system
Ciancio, A. L., Cordella, F., Barone, R., Romeo, R. A., Bellingegni, A. D., Sacchetti, R., Davalli, A., Di Pino, G., Ranieri, F., Di Lazzaro, V., et al. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00116 · Cited by 131
Stanney, K., Samman, S., Reeves, L., Hale, K., Buff, W., Bowers, C., Goldiez, B., Nicholson, D., & Lackey, S. (2004) · International Journal of Human-Computer Interaction · doi:10.1207/s15327590ijhc1702_7 · Cited by 65
“(cid:127) Use caution when implementing finger tip haptic devices for tasks requiring sustained force because they can only exert 4.7 N over sustained periods (Shimoga, 1993).”
BackgroundInfluential
Metadata
- Authors
- Shimoga, K. B.
- Venue
- Proceedings of IEEE Virtual Reality Annual International Symposium
- Publisher
- IEEE
- Published
- 2002-12-30
- Pages
- 263-270
- OpenAlex
- W4252366120
- Cited by
- 92
- References
- 1
- FWCI
- 16.42
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A survey of perceptual feedback issues in dexterous telemanipulation. I. Finger force feedback. https://app.cochat.ai/papers/10.1109/vrais.1993.380770
- The paper
- Shimoga, K. B. (2002). A survey of perceptual feedback issues in dexterous telemanipulation. I. Finger force feedback. Proceedings of IEEE Virtual Reality Annual International Symposium. https://doi.org/10.1109/vrais.1993.380770
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.