Vibrotactile feedback system for intuitive upper-limb rehabilitation
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The proposed demonstration stems from research on a low cost haptic virtual interaction platform for upper-limb rehabilitation. This work centers on the use of vibrotactile feedback in a virtual environment to help stroke patients perform simple repetitive motions and thereby overcome motor planning deficits. The device to be demonstrated consists of a sleeve with embedded optical markers and vibration actuators. When in use, the system has three main functions: it continually measures the configuration of the patient's arm in space, it provides graphical feedback about the desired arm configuration and the user's current arm configuration on a computer monitor, and it provides intuitive vibrotactile cues to guide the user's arm into the target configuration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multisensory perception: Beyond modularity and convergence
Driver, J., & Spence, C. (2000) · Current Biology · doi:10.1016/s0960-9822(00)00740-5 · Cited by 465 · cited 1×
“Through this demonstration, conference attendees will be able to experience the synergy between different sensory modalities [5] that can guide them to perform simple tasks with help of intuitive tactile cues.”
Virtual Environment Training Improves Motor Performance in Two Patients with Stroke: Case Report
Holden, M., Todorov, E., Callahan, J., & Bizzi, E. (1999) · Neurology Report · doi:10.1097/01253086-199923020-00013 · Cited by 117
Cited by
Exoskeleton robots for upper-limb rehabilitation: State of the art and future prospects
Lo, H. S., & Xie, S. Q. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.10.004 · Cited by 571
Kim, W.-S., Cho, S., Ku, J., Kim, Y., Lee, K., Hwang, H.-J., & Paik, N.-J. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9103369 · Cited by 226
“, 2009 [61] Wearable and nonwearable Sleeve for optical tracking (camera) T, V NI Arm”
BackgroundLessons in using vibrotactile feedback to guide fast arm motions
Bark, K., Khanna, P., Irwin, R., Kapur, P., Jax, S. A., Buxbaum, L. J., & Kuchenbecker, K. J. (2011) · 2011 IEEE World Haptics Conference · doi:10.1109/whc.2011.5945512 · Cited by 63
“Other applications using similar methodologies include dance training [2], stroke rehabilitation [4,5], rowing [8,13], gait retraining [9], and snowboarding [11].”
BackgroundMethodSelf-citation
Metadata
- Authors
- Kapur, P., Premakumar, S., Jax, S. A., Buxbaum, L. J., Dawson, A. M., & Kuchenbecker, K. J.
- Venue
- World Haptics 2009 - Third Joint EuroHaptics conference and Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems
- Publisher
- IEEE
- Published
- 2009
- Pages
- 621-622
- OpenAlex
- W2152127911
- Cited by
- 44
- References
- 2
- FWCI
- 3.67
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Vibrotactile feedback system for intuitive upper-limb rehabilitation. https://app.cochat.ai/papers/10.1109/whc.2009.4810918
- The paper
- Kapur, P., Premakumar, S., Jax, S. A., Buxbaum, L. J., Dawson, A. M., & Kuchenbecker, K. J. (2009). Vibrotactile feedback system for intuitive upper-limb rehabilitation. World Haptics 2009 - Third Joint EuroHaptics conference and Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems. https://doi.org/10.1109/whc.2009.4810918
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.