The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Microwave‐enhanced enzyme reaction for protein mapping by mass spectrometry: A new approach to protein digestion in minutes
Open accessAbstract
Accelerated proteolytic cleavage of proteins under controlled microwave irradiation has been achieved. Selective peptide fragmentation by endoproteases trypsin or lysine C led to smaller peptides that were analyzed by matrix‐assisted laser desorption ionization (MALDI) or liquid chromatography‐electrospray ionization (LC‐ESI) techniques. The efficacy of this technique for protein mapping was demonstrated by the mass spectral analyses of the peptide fragmentation of several biologically active proteins, including cytochrome c, ubiquitin, lysozyme, myoglobin, and interferon α‐2b. Most important, using this novel approach digestion of proteins occurs in minutes, in contrast to the hours required by conventional methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
Cited by
Controlled Microwave Heating in Modern Organic Synthesis
Kappe, C. O. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200400655 · Cited by 3,607
Synthesis of Core/Shell Colloidal Magnetic Zeolite Microspheres for the Immobilization of Trypsin
Deng, Y., Deng, C., Qi, D., Liu, C., Liu, J., Zhang, X., & Zhao, D. (2009) · Advanced Materials · doi:10.1002/adma.200801766 · Cited by 298
Quantification of seven apolipoproteins in human plasma by proteotypic peptides using fast LC‐MS/MS
Ceglarek, U., Dittrich, J., Becker, S., Baumann, F., Kortz, L., & Thiery, J. (2013) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201300034 · Cited by 38
Metadata
- Authors
- Pramanik, B. N., Mirza, U. A., Ing, Y. H., Liu, Y., Bartner, P. L., Weber, P. C., & Bose, A. K.
- Venue
- Protein Science
- Publisher
- Wiley
- Published
- 2002-11
- Volume
- 11
- Issue
- 11
- Pages
- 2676-2687
- ISSN
- 0961-8368 (ISSN-L)
- 1469-896X
- OpenAlex
- W2135119375
- Cited by
- 224
- References
- 2
- FWCI
- 2.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microwave‐enhanced enzyme reaction for protein mapping by mass spectrometry: A new approach to protein digestion in minutes. https://app.cochat.ai/papers/10.1110/ps.0213702
- The paper
- Pramanik, B. N., Mirza, U. A., Ing, Y. H., Liu, Y., Bartner, P. L., Weber, P. C., & Bose, A. K. (2002). Microwave‐enhanced enzyme reaction for protein mapping by mass spectrometry: A new approach to protein digestion in minutes. Protein Science. https://doi.org/10.1110/ps.0213702
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.