CoChat

Performance of two Aspergillus IgG EIA assays compared with the precipitin test in chronic and allergic aspergillosis

Open access
Baxter, C.G., Denning, D.W., Jones, A.M., Todd, A., Moore, C.B., Richardson, M.D. · 2013 · Clinical Microbiology and Infection
Cited by 99

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Detection of Aspergillus IgG antibodies is important in the diagnosis of chronic pulmonary aspergillosis and allergic bronchopulmonary aspergillosis. Immunoprecipitation techniques to detect these antibodies appear to lack sensitivity and accurate quantitation compared with enzyme immunoassays (EIA). This study assessed the performance of two commercial EIAs compared with counterimmunoelectrophoresis (CIE). This was a prospective cohort study of 175 adult patients with chronic or allergic pulmonary aspergillosis. Aspergillus IgG antibodies were detected using CIE, Phadia ImmunoCap Aspergillus IgG and Bio-Rad Platelia Aspergillus IgG. Inter-assay reproducibility was determined for each method and 25 patients had two serum samples analysed within a 6-month interval. When compared with CIE, both ImmunoCap and Platelia Aspergillus IgG had good sensitivity (97 and 93%, respectively) for detection of Aspergillus IgG antibodies. The level of agreement between the two EIAs for positive results was good, but the concentration of antibodies was not correlated between the tests or with CIE titre. ImmunoCap IgG inter-assay coefficient of variation was 5%, whereas Platelia IgG was 33%. Median ImmunoCap IgG values for CPA and allergic aspergillosis were 95 and 32 mg/L, respectively, whereas Platelia IgG values were >80 and 6 AU/mL. The direction of CIE titre change over 6 months was mirrored by ImmunoCap IgG levels in 92% of patients, and by Platelia IgG in 72% of patients. Both ImmunoCap and Platelia Aspergillus IgG EIAs are sensitive measures of Aspergillus IgG antibodies compared with CIE. However, ImmunoCap appears to have better reproducibility and may be more suitable for monitoring patient disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/1469-0691.12133

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Baxter, C. G., Denning, D. W., Jones, A. M., Todd, A., Moore, C. B., & Richardson, M. D.
Venue
Clinical Microbiology and Infection
Publisher
Elsevier BV
Published
2013-04
Volume
19
Issue
4
Pages
E197-E204
ISSN
1198-743X (ISSN-L)
OpenAlex
W2136652646
Cited by
99
References
4
FWCI
4.05
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.