The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Biosensors for rapid detection of Salmonella in food: A review
Abstract
Salmonella is one of the main causes of foodborne infectious diseases, posing a serious threat to public health. It can enter the food supply chain at various stages of production, processing, distribution, and marketing. High prevalence of Salmonella necessitates efficient and effective approaches for its identification, detection, and monitoring at an early stage. Because conventional methods based on plate counting and real‐time polymerase chain reaction are time‐consuming and laborious, novel rapid detection methods are urgently needed for in‐field and on‐line applications. Biosensors provide many advantages over conventional laboratory assays in terms of sensitivity, specificity, and accuracy, and show superiority in rapid response and potential portability. They are now recognized as promising alternative tools and one of the most on‐site applicable and end user–accessible methods for rapid detection. In recent years, we have witnessed a flourishing of studies in the development of robust and elaborate biosensors for detection of Salmonella in food. This review aims to provide a comprehensive overview on Salmonella biosensors by highlighting different signal‐transducing mechanisms (optical, electrochemical, piezoelectric, etc.) and critically analyzing its recent trends, particularly in combination with nanomaterials, microfluidics, portable instruments, and smartphones. Furthermore, current challenges are emphasized and future perspectives are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intrinsic peroxidase-like activity of ferromagnetic nanoparticles
Gao, L., Zhuang, J., Nie, L., Zhang, J., Zhang, Y., Gu, N., Wang, T., Feng, J., Yang, D., Perrett, S., et al. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.260 · Cited by 7,483
Raman spectra of pyridine adsorbed at a silver electrode
Fleischmann, M., Hendra, P. J., & McQuillan, A. J. (1974) · Chemical Physics Letters · doi:10.1016/0009-2614(74)85388-1 · Cited by 7,172
Smartphone-based biosensors: A critical review and perspectives
Roda, A., Michelini, E., Zangheri, M., Di Fusco, M., Calabria, D., & Simoni, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.10.019 · Cited by 520
Artificial intelligence biosensors: Challenges and prospects
Jin, X., Liu, C., Xu, T., Su, L., & Zhang, X. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112412 · Cited by 399
Futuristic biosensors for cardiac health care: an artificial intelligence approach
Vashistha, R., Dangi, A. K., Kumar, A., Chhabra, D., & Shukla, P. (2018) · 3 Biotech · doi:10.1007/s13205-018-1368-y · Cited by 113
Cited by
Chen, S., Zhu, P., Mao, L., Wu, W., Lin, H., Xu, D., Lu, X., & Shi, J. (2023) · Advanced Materials · doi:10.1002/adma.202208256 · Cited by 363
Zhou, E., Li, Q., Zhu, D., Chen, G., & Wu, L. (2024) · Food Science and Human Wellness · doi:10.26599/fshw.2022.9250095 · Cited by 37
Metadata
- Authors
- Shen, Y., Xu, L., & Li, Y.
- Venue
- Comprehensive Reviews in Food Science and Food Safety
- Publisher
- Wiley
- Published
- 2020-11-11
- Volume
- 20
- Issue
- 1
- Pages
- 149-197
- ISSN
- 1541-4337 (ISSN-L)
- OpenAlex
- W3100168758
- Cited by
- 201
- References
- 5
- FWCI
- 6.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biosensors for rapid detection of Salmonella in food: A review. https://app.cochat.ai/papers/10.1111/1541-4337.12662
- The paper
- Shen, Y., Xu, L., & Li, Y. (2021). Biosensors for rapid detection of Salmonella in food: A review. Comprehensive Reviews in Food Science and Food Safety. https://doi.org/10.1111/1541-4337.12662
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.