Cited by 48Clinical Nutrition and GastroenterologyMechanical Circulatory Support DevicesHemodynamic Monitoring and Therapy

Energy expenditure of patients on ECMO: A prospective pilot study

De Waele, Elisabeth, Jonckheer, Joop, Pen, Joeri J., Demol, Joy, Staessens, Kurt, Puis, Luc, La Meir, Mark, Honoré, Patrick M. +2 more·2019·Acta Anaesthesiologica Scandinavica

Abstract

Background An optimal nutritional approach sustained by convenient monitoring of metabolic status and reliable assessment of energy expenditure (EE) may improve the outcome of critically ill patients on extracorporeal membrane oxygenation (ECMO). We previously demonstrated the feasibility of indirect calorimetry (IC)-the standard of care technique to determine caloric targets-in patients undergoing ECMO. This study aims to compare measured with calculated EE during ECMO treatment. We additionally provide median EE values for use in settings where IC is not available. Methods IC was performed in seven stable ECMO patients. Gas exchange was analyzed at the ventilator, and ECMO side and values were introduced in a modified Weir formula to calculate resting EE. Results were compared with EE calculated with the Harris-Benedict equation and with the 25 kcal/kg/day ESPEN recommendation. Results Total median oxygen consumption rate was 196 (Q1-Q3 158-331) mL/min, and total median carbon dioxide production was 150 (Q1-Q3 104-203) mL/min. Clinically relevant differences between calculated and measured EE were observed in all patients. The median EE was 1334 (Q1-Q3 1134-2119) kcal/24 hours or 18 (Q1-Q3 15-27) kcal/kg/day. Conclusion Compared with measured EE, calculation of EE both over- and underestimated caloric needs during ECMO treatment. Despite a median EE of 21 kcal/kg/day, large variability in metabolic rate was found and demands further investigation.

Integrity signals

Registry

Crossref · 10.1111/aas.13287

Cites

0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
De Waele, E., Jonckheer, J., Pen, J. J., Demol, J., Staessens, K., Puis, L., La Meir, M., Honoré, P. M., L. N. G. Malbrain, M., & Spapen, H. D.
Affiliations
  • Intensive Care Unit, UZ Brussel Vrije Universiteit Brussel (VUB) Brussels Belgium
  • Vrije Universiteit Brussel (BE)
  • Department of cardiac surgery, UZ Brussel Vrije Universiteit Brussel (VUB) Brussels Belgium
Venue
Acta Anaesthesiologica Scandinavica
Publisher
Wiley
Published
2018-11-06
Volume
63
Issue
3
Pages
360-364
ISSN
  • 0001-5172 (ISSN-L)
  • 1399-6576
OpenAlex
W2899840399
Cited by
48
References
0
Citations by year
2026: 8 · 2025: 5 · 2024: 4 · 2023: 7 · 2022: 8 · 2021: 10 · 2020: 4 · 2019: 2
FWCI
3.30
Type
journal article
Language
en
Open access
closed
Locations
  • Acta Anaesthesiologica Scandinavica (publishedVersion)
  • PubMed (publishedVersion)
  • VUBIR (Vrije Universiteit Brussel) (submittedVersion)
Topics
  • Health Sciences › Nursing › Nutrition and Dietetics › Clinical Nutrition and Gastroenterology
  • Physical Sciences › Engineering › Biomedical Engineering › Mechanical Circulatory Support Devices
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
Keywords
extracorporeal membrane oxygenation, energy expenditure, indirect calorimetry, resting energy expenditure, Harris-Benedict equation, oxygen consumption, CO2 emissions, critically ill patients, nutritional support, metabolic rate
MeSH terms
Aged, Calorimetry, Indirect, Carbon Dioxide, Energy Metabolism, Female, Humans, Male, Middle Aged, Oxygen Consumption, Pilot Projects, Prospective Studies, Pulmonary Gas Exchange, Rest, Extracorporeal Membrane Oxygenation, Critical Illness

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review