The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Point-of-care Ultrasonography for the Diagnosis of Acute Cardiogenic Pulmonary Edema in Patients Presenting With Acute Dyspnea: A Systematic Review and Meta-analysis
Open accessAbstract
OBJECTIVES: Acute dyspnea is a common presenting complaint to the emergency department (ED), and point-of-care (POC) lung ultrasound (US) has shown promise as a diagnostic tool in this setting. The primary objective of this systematic review was to determine the sensitivity and specificity of US using B-lines in diagnosing acute cardiogenic pulmonary edema (ACPE) in patients presenting to the ED with acute dyspnea. METHODS: A systematic review protocol adhering to Cochrane Handbook guidelines was created to guide the search and analysis, and we searched the following databases: PubMed, EMBASE, Ovid MEDLINE, Ovid MEDLINE In-Process & Other Non-Indexed Citations, and the Cochrane Database of Systematic Reviews. References of reviewed articles were hand-searched, and electronic searches of conference abstracts from major emergency medicine, cardiology, and critical care conferences were conducted. The authors included prospective cohort and prospective case-control studies that recruited patients presenting to hospital with symptomatic, acute dyspnea, or where there was a clinical suspicion of congestive heart failure, and reported the sensitivity and specificity of B-lines in diagnosing ACPE. Studies of asymptomatic individuals or in patients where there was no suspicion of ACPE were excluded. The outcome of interest was a diagnosis of ACPE using US B-lines. A final diagnosis from clinical follow-up was accepted as the reference standard. Two reviewers independently reviewed all citations to assess for inclusion, abstracted data, and assessed included studies for methodologic quality using the QUADAS-2 tool. Contingency tables were used to calculate sensitivity and specificity. Three subgroup analyses were planned a priori to examine the effects of the type of study, patient population, and lung US protocol employed. RESULTS: Seven articles (n = 1,075) were identified that met inclusion criteria (two studies completed in the ED, two in the intensive care unit [ICU], two on inpatient wards, and one in the prehospital setting). The seven studies were rated as average to excellent methodologic quality. The sensitivity of US using B-lines to diagnosis ACPE is 94.1% (95% confidence interval [CI] = 81.3% to 98.3%) and the specificity is 92.4% (95% CI = 84.2% to 96.4%). Preplanned subgroup analyses did not reveal statistically significant changes in the overall summary estimates, nor did exclusion of three potential outlier studies. CONCLUSIONS: This study suggests that in patients with a moderate to high pretest probability for ACPE, an US study showing B-lines can be used to strengthen an emergency physician's working diagnosis of ACPE. In patients with a low pretest probability for ACPE, a negative US study can almost exclude the possibility of ACPE. Further studies including large numbers of ED patients presenting with undifferentiated dyspnea are required to gain more valid and reliable estimates of test accuracy in ED patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Heart Disease and Stroke Statistics—2012 Update: A Report From the American Heart Association
Writing Group Members, Roger, V. L., Go, A. S., Lloyd-Jones, D. M., Benjamin, E. J., Berry, J. D., Borden, W. B., Bravata, D. M., Dai, S., Ford, E. S., et al. (2012) · Circulation · doi:10.1161/cir.0b013e31823ac046 · Cited by 7,333
Assessing Bias in Studies of Prognostic Factors
Hayden, J. A., van der Windt, D. A., Cartwright, J. L., Côté, P., & Bombardier, C. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-158-4-201302190-00009 · Cited by 3,287
Residuals and Influence in Regression
Ling, R. F. (1984) · Technometrics · doi:10.1080/00401706.1984.10487996 · Cited by 2,642
Relevance of Lung Ultrasound in the Diagnosis of Acute Respiratory Failure*: The BLUE Protocol
Lichtenstein, D. A., & Mezière, G. A. (2008) · Chest · doi:10.1378/chest.07-2800 · Cited by 2,068
Residuals and Influence in Regression.
Atkinson, A. C., Cook, R. D., & Weisberg, S. (1983) · Biometrics · doi:10.2307/2531125 · Cited by 1,904
A hierarchical regression approach to meta‐analysis of diagnostic test accuracy evaluations
Rutter, C. M., & Gatsonis, C. A. (2001) · Statistics in Medicine · doi:10.1002/sim.942 · Cited by 1,505
Moses, L. E., Shapiro, D., & Littenberg, B. (1993) · Statistics in Medicine · doi:10.1002/sim.4780121403 · Cited by 1,405
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
“Ultrasound Comet-Tail Images”: A Marker Of Pulmonary Edema
Agricola, E., Bove, T., Oppizzi, M., Marino, G., Zangrillo, A., Margonato, A., & Picano, E. (2005) · Chest · doi:10.1378/chest.127.5.1690 · Cited by 597
Cited by
Mullens, W., Damman, K., Harjola, V.-P., Mebazaa, A., Brunner-La Rocca, H.-P., Martens, P., Testani, J. M., Tang, W. H. W., Orso, F., Rossignol, P., et al. (2019) · European Journal of Heart Failure · doi:10.1002/ejhf.1369 · Cited by 1,119
Harjola, V.-P., Mullens, W., Banaszewski, M., Bauersachs, J., Brunner-La Rocca, H.-P., Chioncel, O., Collins, S. P., Doehner, W., Filippatos, G. S., Flammer, A. J., et al. (2017) · European Journal of Heart Failure · doi:10.1002/ejhf.872 · Cited by 430
Diagnosing Acute Heart Failure in the Emergency Department: A Systematic Review and Meta‐analysis
Martindale, J. L., Wakai, A., Collins, S. P., Levy, P. D., Diercks, D., Hiestand, B. C., Fermann, G. J., deSouza, I., & Sinert, R. (2016) · Academic Emergency Medicine · doi:10.1111/acem.12878 · Cited by 368
New International Guidelines and Consensus on the Use of Lung Ultrasound
Demi, L., Wolfram, F., Klersy, C., De Silvestri, A., Ferretti, V. V., Muller, M., Miller, D., Feletti, F., Wełnicki, M., Buda, N., et al. (2023) · Journal of Ultrasound in Medicine · doi:10.1002/jum.16088 · Cited by 328
Maw, A. M., Hassanin, A., Ho, P. M., McInnes, M. D. F., Moss, A., Juarez-Colunga, E., Soni, N. J., Miglioranza, M. H., Platz, E., DeSanto, K., et al. (2019) · JAMA Network Open · doi:10.1001/jamanetworkopen.2019.0703 · Cited by 309
Metadata
- Authors
- Al Deeb, M., Barbic, S., Featherstone, R., Dankoff, J., & Barbic, D.
- Venue
- Academic Emergency Medicine
- Publisher
- Wiley
- Published
- 2014-08
- Volume
- 21
- Issue
- 8
- Pages
- 843-852
- ISSN
- 1069-6563 (ISSN-L)
- OpenAlex
- W2010708286
- Cited by
- 330
- References
- 27
- FWCI
- 3.45
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Point-of-care Ultrasonography for the Diagnosis of Acute Cardiogenic Pulmonary Edema in Patients Presenting With Acute Dyspnea: A Systematic Review and Meta-analysis. https://app.cochat.ai/papers/10.1111/acem.12435
- The paper
- Al Deeb, M., Barbic, S., Featherstone, R., Dankoff, J., & Barbic, D. (2014). Point-of-care Ultrasonography for the Diagnosis of Acute Cardiogenic Pulmonary Edema in Patients Presenting With Acute Dyspnea: A Systematic Review and Meta-analysis. Academic Emergency Medicine. https://doi.org/10.1111/acem.12435
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.