Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 309

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Diagnostic Accuracy of Point-of-Care Lung Ultrasonography and Chest Radiography in Adults With Symptoms Suggestive of Acute Decompensated Heart Failure: A Systematic Review and Meta-analysis

Open access
Maw, Anna M., Hassanin, Ahmed, Ho, P. Michael, McInnes, Matthew D. F., Moss, Angela, Juarez-Colunga, Elizabeth, Soni, Nilam J., Miglioranza, Marcelo H., Platz, Elke, DeSanto, Kristen, Sertich, Anthony P., Salame, Gerald, Daugherty, Stacie L.·2019·JAMA Network Open

Abstract

Importance: Standard tools used to diagnose pulmonary edema in acute decompensated heart failure (ADHF), including chest radiography (CXR), lack adequate sensitivity, which may delay appropriate diagnosis and treatment. Point-of-care lung ultrasonography (LUS) may be more accurate than CXR, but no meta-analysis of studies directly comparing the 2 tools was previously available. Objective: To compare the accuracy of LUS with the accuracy of CXR in the diagnosis of cardiogenic pulmonary edema in adult patients presenting with dyspnea. Data Sources: A comprehensive search of MEDLINE, Embase, and Cochrane Library databases and the gray literature was performed in May 2018. No language or year limits were applied. Study Selection: Study inclusion criteria were a prospective adult cohort of patients presenting to any clinical setting with dyspnea who underwent both LUS and CXR on initial assessment with imaging results compared with a reference standard ADHF diagnosis by a clinical expert after either a medical record review or a combination of echocardiography findings and brain-type natriuretic peptide criteria. Two reviewers independently assessed the studies for inclusion criteria, and disagreements were resolved with discussion. Data Extraction and Synthesis: Reporting adhered to the Cochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy and the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Two authors independently extracted data and assessed the risk of bias using a customized QUADAS-2 tool. The pooled sensitivity and specificity of LUS and CXR were determined using a hierarchical summary receiver operating characteristic approach. Main Outcomes and Measures: The comparative accuracy of LUS and CXR in diagnosing ADHF as measured by the differences between the 2 modalities in pooled sensitivity and specificity. Results: The literature search yielded 1377 nonduplicate titles that were screened, of which 43 articles (3.1%) underwent full-text review. Six studies met the inclusion criteria, representing a total of 1827 patients. Pooled estimates for LUS were 0.88 (95% Cl, 0.75-0.95) for sensitivity and 0.90 (95% Cl, 0.88-0.92) for specificity. Pooled estimates for CXR were 0.73 (95% CI, 0.70-0.76) for sensitivity and 0.90 (95% CI, 0.75-0.97) for specificity. The relative sensitivity ratio of LUS, compared with CXR, was 1.2 (95% CI, 1.08-1.34; P < .001), but no difference was found in specificity between tests (relative specificity ratio, 1.0; 95% CI, 0.90-1.11; P = .96). Conclusions and Relevance: The findings suggest that LUS is more sensitive than CXR in detecting pulmonary edema in ADHF; LUS should be considered as an adjunct imaging modality in the evaluation of patients with dyspnea at risk of ADHF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jamanetworkopen.2019.0703

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 38 references

Cited by

See all 309

Metadata

Authors
Maw, A. M., Hassanin, A., Ho, P. M., McInnes, M. D. F., Moss, A., Juarez-Colunga, E., Soni, N. J., Miglioranza, M. H., Platz, E., DeSanto, K., Sertich, A. P., Salame, G., & Daugherty, S. L.
Venue
JAMA Network Open
Published
2019-03-15
Volume
2
Issue
3
Pages
e190703
ISSN
2574-3805 (ISSN-L)
OpenAlex
W2920799198
Cited by
309
References
38
FWCI
29.37
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic Accuracy of Point-of-Care Lung Ultrasonography and Chest Radiography in Adults With Symptoms Suggestive of Acute Decompensated Heart Failure: A Systematic Review and Meta-analysis. https://app.cochat.ai/papers/10.1001/jamanetworkopen.2019.0703
The paper
Maw, A. M., Hassanin, A., Ho, P. M., McInnes, M. D. F., Moss, A., Juarez-Colunga, E., Soni, N. J., Miglioranza, M. H., Platz, E., DeSanto, K., Sertich, A. P., Salame, G., & Daugherty, S. L. (2019). Diagnostic Accuracy of Point-of-Care Lung Ultrasonography and Chest Radiography in Adults With Symptoms Suggestive of Acute Decompensated Heart Failure: A Systematic Review and Meta-analysis. JAMA Network Open. https://doi.org/10.1001/jamanetworkopen.2019.0703

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.