The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Diagnostic Accuracy of Point-of-Care Lung Ultrasonography and Chest Radiography in Adults With Symptoms Suggestive of Acute Decompensated Heart Failure: A Systematic Review and Meta-analysis
Open accessAbstract
Importance: Standard tools used to diagnose pulmonary edema in acute decompensated heart failure (ADHF), including chest radiography (CXR), lack adequate sensitivity, which may delay appropriate diagnosis and treatment. Point-of-care lung ultrasonography (LUS) may be more accurate than CXR, but no meta-analysis of studies directly comparing the 2 tools was previously available. Objective: To compare the accuracy of LUS with the accuracy of CXR in the diagnosis of cardiogenic pulmonary edema in adult patients presenting with dyspnea. Data Sources: A comprehensive search of MEDLINE, Embase, and Cochrane Library databases and the gray literature was performed in May 2018. No language or year limits were applied. Study Selection: Study inclusion criteria were a prospective adult cohort of patients presenting to any clinical setting with dyspnea who underwent both LUS and CXR on initial assessment with imaging results compared with a reference standard ADHF diagnosis by a clinical expert after either a medical record review or a combination of echocardiography findings and brain-type natriuretic peptide criteria. Two reviewers independently assessed the studies for inclusion criteria, and disagreements were resolved with discussion. Data Extraction and Synthesis: Reporting adhered to the Cochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy and the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Two authors independently extracted data and assessed the risk of bias using a customized QUADAS-2 tool. The pooled sensitivity and specificity of LUS and CXR were determined using a hierarchical summary receiver operating characteristic approach. Main Outcomes and Measures: The comparative accuracy of LUS and CXR in diagnosing ADHF as measured by the differences between the 2 modalities in pooled sensitivity and specificity. Results: The literature search yielded 1377 nonduplicate titles that were screened, of which 43 articles (3.1%) underwent full-text review. Six studies met the inclusion criteria, representing a total of 1827 patients. Pooled estimates for LUS were 0.88 (95% Cl, 0.75-0.95) for sensitivity and 0.90 (95% Cl, 0.88-0.92) for specificity. Pooled estimates for CXR were 0.73 (95% CI, 0.70-0.76) for sensitivity and 0.90 (95% CI, 0.75-0.97) for specificity. The relative sensitivity ratio of LUS, compared with CXR, was 1.2 (95% CI, 1.08-1.34; P < .001), but no difference was found in specificity between tests (relative specificity ratio, 1.0; 95% CI, 0.90-1.11; P = .96). Conclusions and Relevance: The findings suggest that LUS is more sensitive than CXR in detecting pulmonary edema in ADHF; LUS should be considered as an adjunct imaging modality in the evaluation of patients with dyspnea at risk of ADHF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab670 · Cited by 19,442
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
2013 ACCF/AHA Guideline for the Management of Heart Failure
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.05.019 · Cited by 12,536
2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure
Ponikowski, P., Voors, A. A., Anker, S. D., Bueno, H., Cleland, J. G. F., Coats, A. J. S., Falk, V., González-Juanatey, J. R., Harjola, V.-P., Jankowska, E. A., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw128 · Cited by 11,429
McInnes, M. D. F., Moher, D., Thombs, B. D., McGrath, T. A., Bossuyt, P. M., and the PRISMA-DTA Group, Clifford, T., Cohen, J. F., Deeks, J. J., Gatsonis, C., et al. (2018) · JAMA · doi:10.1001/jama.2017.19163 · Cited by 3,210
Self-citationInternational evidence-based recommendations for point-of-care lung ultrasound
International Liaison Committee on Lung Ultrasound (ILC-LUS) for the International Consensus Conference on Lung Ultrasound (ICC-LUS), Volpicelli, G., Elbarbary, M., Blaivas, M., Lichtenstein, D. A., Mathis, G., Kirkpatrick, A. W., Melniker, L., Gargani, L., Noble, V. E., et al. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2513-4 · Cited by 2,874
Computing inter‐rater reliability and its variance in the presence of high agreement
Gwet, K. L. (2008) · British Journal of Mathematical and Statistical Psychology · doi:10.1348/000711006x126600 · Cited by 2,167
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31829e8776 · Cited by 2,106
A hierarchical regression approach to meta‐analysis of diagnostic test accuracy evaluations
Rutter, C. M., & Gatsonis, C. A. (2001) · Statistics in Medicine · doi:10.1002/sim.942 · Cited by 1,505
Moses, L. E., Shapiro, D., & Littenberg, B. (1993) · Statistics in Medicine · doi:10.1002/sim.4780121403 · Cited by 1,405
Cited by
2022 AHA/ACC/HFSA Guideline for the Management of Heart Failure
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.12.012 · Cited by 2,862
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001063 · Cited by 4,922
New International Guidelines and Consensus on the Use of Lung Ultrasound
Demi, L., Wolfram, F., Klersy, C., De Silvestri, A., Ferretti, V. V., Muller, M., Miller, D., Feletti, F., Wełnicki, M., Buda, N., et al. (2023) · Journal of Ultrasound in Medicine · doi:10.1002/jum.16088 · Cited by 328
Adedinsewo, D., Carter, R. E., Attia, Z., Johnson, P., Kashou, A. H., Dugan, J. L., Albus, M., Sheele, J. M., Bellolio, F., Friedman, P. A., et al. (2020) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.120.008437 · Cited by 169
Metadata
- Authors
- Maw, A. M., Hassanin, A., Ho, P. M., McInnes, M. D. F., Moss, A., Juarez-Colunga, E., Soni, N. J., Miglioranza, M. H., Platz, E., DeSanto, K., Sertich, A. P., Salame, G., & Daugherty, S. L.
- Venue
- JAMA Network Open
- Publisher
- American Medical Association (AMA)
- Published
- 2019-03-15
- Volume
- 2
- Issue
- 3
- Pages
- e190703
- ISSN
- 2574-3805 (ISSN-L)
- OpenAlex
- W2920799198
- Cited by
- 309
- References
- 38
- FWCI
- 29.37
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic Accuracy of Point-of-Care Lung Ultrasonography and Chest Radiography in Adults With Symptoms Suggestive of Acute Decompensated Heart Failure: A Systematic Review and Meta-analysis. https://app.cochat.ai/papers/10.1001/jamanetworkopen.2019.0703
- The paper
- Maw, A. M., Hassanin, A., Ho, P. M., McInnes, M. D. F., Moss, A., Juarez-Colunga, E., Soni, N. J., Miglioranza, M. H., Platz, E., DeSanto, K., Sertich, A. P., Salame, G., & Daugherty, S. L. (2019). Diagnostic Accuracy of Point-of-Care Lung Ultrasonography and Chest Radiography in Adults With Symptoms Suggestive of Acute Decompensated Heart Failure: A Systematic Review and Meta-analysis. JAMA Network Open. https://doi.org/10.1001/jamanetworkopen.2019.0703
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.