Efficacy of AccuVein to Facilitate Peripheral Intravenous Placement in Adults Presenting to an Emergency Department: A Randomized Clinical Trial
The DOI matches its Crossref record.
Abstract
OBJECTIVES: In the emergency department (ED), intravenous (IV) catheter placement is one of the most frequent interventions and may be a real challenge in some conditions. Improvement of the success rate with new technology represents a great opportunity. This randomized controlled trial aimed to show the superiority of AccuVein to cannulate veins in adults compared to routine care. METHODS: After giving written consent, patients were randomized into two groups: routine IV catheter insertion or insertion guided by the AccuVein, which is a hand-held instrument displaying laser light to optimize visualization of veins. The primary outcome was the time to successful placement of catheters. Secondary outcomes included the number of attempts, the rate of failure, technique-related pain, occurrence of movements, and efficiency of IV cannulation as perceived by the operator when using the AccuVein device. Results are given as mean and bootstrapped 95% confidence interval (CI) and percentages. p-values of <0.05 were considered significant. RESULTS: A total of 266 six patients were included, with 157 randomized to routine cannulation and 115 to AccuVein. Patient characteristics were similar. Time to successful placement of IV catheter (routine, 98 seconds, 95% CI = 85 to 113 seconds; and AccuVein, 119 seconds, 95% CI = 93 to 154 seconds) was not different between groups (p = 0.24). Secondary outcomes (failure and pain) did not significantly differ, except for movements, which were more frequent when using the AccuVein device (19.1% vs. 10.2%, p = 0.05). Evaluation of the AccuVein by operators was more often negative than positive. CONCLUSIONS: Use of the AccuVein did not improve IV cannulation in nonselected ED patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Carr, P. J., Rippey, J. C. R., Budgeon, C. A., Cooke, M. L., Higgins, N., & Rickard, C. M. (2016) · The Journal of Vascular Access · doi:10.5301/jva.5000487 · Cited by 122
Carr, P. J., Higgins, N. S., Cooke, M. L., Rippey, J., & Rickard, C. M. (2017) · Journal of Hospital Medicine · doi:10.12788/jhm.2836 · Cited by 77
DAT, M., JC, D. L. T.-M., AC, N., Reis, R., MH, B., & SEM, T. (2021) · The Journal of Vascular Access · doi:10.1177/1129729820939335 · Cited by 21
Yalçınlı, S., Karbek Akarca, F., Can, Ö., Uz, İ., & Konakçı, G. (2022) · Prehospital and Disaster Medicine · doi:10.1017/s1049023x21001217 · Cited by 23
Waller, D., Mondy, P., Brama, T., Fisher, J., King, A., Malkov, K., Wall‐Smith, D., Ryan, L., & Irving, D. O. (2016) · Vox Sanguinis · doi:10.1111/vox.12407 · Cited by 9
Metadata
- Authors
- Aulagnier, J., Hoc, C., Mathieu, E., Dreyfus, J. F., Fischler, M., & Le Guen, M.
- Venue
- Academic Emergency Medicine
- Publisher
- Wiley
- Published
- 2014-08
- Volume
- 21
- Issue
- 8
- Pages
- 858-863
- ISSN
- 1069-6563 (ISSN-L)
- OpenAlex
- W1996895760
- Cited by
- 75
- References
- 0
- FWCI
- 9.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Efficacy of AccuVein to Facilitate Peripheral Intravenous Placement in Adults Presenting to an Emergency Department: A Randomized Clinical Trial. https://app.cochat.ai/papers/10.1111/acem.12437
- The paper
- Aulagnier, J., Hoc, C., Mathieu, E., Dreyfus, J. F., Fischler, M., & Le Guen, M. (2014). Efficacy of AccuVein to Facilitate Peripheral Intravenous Placement in Adults Presenting to an Emergency Department: A Randomized Clinical Trial. Academic Emergency Medicine. https://doi.org/10.1111/acem.12437
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.