Cited by 4Airway Management and Intubation TechniquesTracheal and airway disordersForeign Body Medical Cases

Evidence is important: safety considerations for emergency catheter cricothyroidotomy

Open access
Marshall, Stuart Duncan·2016·Academic Emergency Medicine

Abstract

It is an unarguable truth that providing appropriate training and equipment leads to improved outcomes in emergencies. Unfortunately, all too often the training and equipment are suboptimal and designed without sufficient attention to current evidence or an appreciation of the context of the emergency. Perhaps the starkest of these examples is in the provision of equipment and training for performance of the emergency surgical airway. A large, nationwide, year-long audit in the United Kingdom has shown that success rates for emergency cricothyroidotomy are highly variable.1 Singled out for particular criticism has been the catheter or “needle” method of accessing the airway and this is likely to be almost solely due to a lack of appropriate equipment and training. This commentary will outline the elements of safe practice of catheter cricothyroidotomy based on evidence from clinical and animal studies. The equipment, technique, and potential complications will be reviewed. The provision of oxygen via a catheter placed through the front of the neck into the trachea was first described by Jacoby and colleagues some 60 years ago.2 Although an inherently risky technique, in the past decade the technique has been scrutinized and refined based on data from elective head and neck surgery, animal, and mannequin-based simulation studies such that complication rates are now significantly lower.3, 4 Catheter cricothyroidotomy provides some advantages over scalpel techniques in terms of lower psychological barriers to perform them and the ability to proceed to other more aggressive techniques should they fail.5 In the hands of appropriately trained practitioners it is likely that failure rates of emergency scalpel and catheter techniques for airway access are similar.6 Only large-bore catheters should be used for access to the airway as they are more resistant to occlusion and provide a more reliable flow of oxygen. A detailed analysis of intravenous catheters shows that smaller gauge devices are more likely to be compressed and to fail during emergency rescue techniques.1, 7 In the UK's 4th National Audit Project (NAP4) of airway management complications, failure occurred in 12 of the 19 attempts at rescue using cricothyroid membrane puncture with a narrow-gauge catheter (<2-mm diameter, equivalent to catheters smaller than 14 gauge).1 Kinking of the device is the commonest complication of percutaneous approaches to the trachea. To prevent kinking the physical properties of the catheter that determine its “memory” (the property of the plastic to return to its original, straight, patent shape after kinking occurs) in addition to the size of the catheter need to be taken into account.7 The use of an InSyte 14-gauge intravenous catheter (Becton Dickinson) as suggested by Heard and colleagues8 has shown to have a lower incidence of occlusion than some purpose made catheters such as the Ravussin (VBM Medizintechnik GmbH-Germany) because of its ability to return to its original shape. Lower-pressure devices such as connection to self-inflating bags provide insufficient pressure to reliably deliver enough oxygen to the alveoli. The success of any attempt at a catheter technique requires that the equipment for high-pressure oxygen insufflation is easy to assemble and predictable for the user. Hospitals in Australia and New Zealand are increasingly stocking prepackaged “can't intubate, can't oxygenate” (CICO) kits in critical care areas such as operating rooms and emergency departments. These kits include a cheap, easy to use device for oxygen delivery such as the RapidO2 (Meditech Systems Ltd) or Enk oxygen flow modulator (Cook Medical). Importantly, these devices also allow venting of insufflated gas via the catheter, even when the upper airway is completely obstructed, provided that adequate time is allowed between each insufflation.8 The conventional caudal angulation of the catheter is advocated for cricothyroid puncture as it has been recognized for many years that angulation of the catheter from the cricothyroid membrane in a cephalad direction leads to a significant chance of damage to the vocal cords from the catheter. In a cadaveric model, vocal cord damage was seen in 8% (3/37) of retrograde intubations and the figure in live patients is estimated to be substantially higher.9 Placement of the catheter must be undertaken using an aspiration technique to ensure the catheter is within the trachea before insufflation occurs. Aspiration of air through a syringe half-filled with saline is preferred during and after placement of the catheter. This minimizes the chance of insufflation of gas into the tissues that will make further attempts at tracheal access more difficult.7 The ability of gas to leave the airway and lungs is of critical importance to prevent barotrauma during catheter insufflation. An oxygen flow of 15 L/min equates to the insufflation of 250 mL/sec making the time required to produce dangerously high intr

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/acem.13037

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Complications associated with jet ventilation are unacceptably high.

    “However, recent reviews have shown that complications associated with jet ventilation are unacceptably high and wire-guided approaches are not as easy or successful as once believed.[114][115][116][117]”

    From Airway Management in Trauma (2018) · cites this paper as [115]

    The opening section acknowledges that catheter oxygenation is inherently risky but says refinements have made complication rates significantly lower. “Evidence of Safety and Need for Ongoing Training” reports few complications when the prescribed technique was used. The paper discusses how to mitigate barotrauma, rather than concluding that complications are unacceptably high. (LLM, conf=0.85)

    Checked by a reasoning model — may be wrong.

    Experimental — accuracy not yet measured
  • Wire-guided approaches are not as easy or successful as once believed.

    “However, recent reviews have shown that complications associated with jet ventilation are unacceptably high and wire-guided approaches are not as easy or successful as once believed.[114][115][116][117]”

    From Airway Management in Trauma (2018) · cites this paper as [115]

    The Type and Size of Catheter section reports failures with narrow-gauge catheter puncture, but does not identify those attempts as wire-guided. Searches for wire-guided, guidewire, and Seldinger approaches found no passage assessing their ease or success. The copy therefore does not establish the attributed claim. (LLM, conf=0.76)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

No references could be resolved yet.

Research works printed but not linked: 7

  1. [1]Cook T, Woodall N, Frerk C. Major complications of airway management in the UK: results of the Fourth National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society. Part 1: Anaesthesia. Br J Anaesth 2011; 106: 617– 31. 21447488
  2. [2]Jacoby JJ, Hamelberg W, Ziegler CH, Florey FA, Jones RJ. Transtracheal resuscitation. J Am Med Assoc 1956; 162: 625– 8. 13366644
  3. [3]Cook TM, Alexander R. Major complications during anaesthesia for elective laryngeal surgery in the UK: a national survey of the use of high‐pressure source ventilation. Br J Anaesth 2008; 101: 266– 72. 18524781
  4. [4]Ross‐Anderson DJ, Ferguson C, Patel A. Transtracheal jet ventilation in 50 patients with severe airway compromise and stridor. Br J Anaesth 2010; 106: 140– 4. 20952426
  5. [6]Langvad S, Hyldmo PK, Nakstad AR, Vist GE, Sandberg M. Emergency cricothyrotomy–a systematic review. Scand J Trauma Resusc Emerg Med 2013; 21: 43. 23725520 PMC3704966
  6. [9]Shantha TR. Retrograde intubation using the subcricoid region. Br J Anaesth 1992; 69: 542– 5. 1739548
  7. [10]Heard AM, Green RJ, Eakins P. The formulation and introduction of a ‘can't intubate, can't ventilate’ algorithm into clinical practice. Anaesthesia 2009; 64: 601– 8. 19453312

Cited by

Sorted by citations

Authors
Marshall, S. D.
Affiliations
Monash University (AU)
Corresponding author
Marshall, Stuart Duncan
Venue
Academic Emergency Medicine
Publisher
Wiley
Published
2016-09
Volume
23
Issue
9
Pages
1074-1076
ISSN
  • 1069-6563 (ISSN-L)
  • 1553-2712
OpenAlex
W2461736131
Cited by
4
References
0
Citations by year
2020: 2 · 2019: 1 · 2017: 1
FWCI
0.98
Type
journal article
Language
en
Open access
Locations
  • Academic Emergency Medicine (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • Monash University Research Portal (Monash University) (publishedVersion, other-oa)
  • PubMed (publishedVersion)
  • Minerva Access (University of Melbourne) (submittedVersion, cc-by-nc)
Funders
Australian and New Zealand College of Anaesthetists
Topics
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Airway Management and Intubation Techniques
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Tracheal and airway disorders
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Foreign Body Medical Cases
Keywords
emergency airway management, emergency surgical airway, catheter kinking, catheter gauge, large-bore catheter, airway complications, airway equipment, airway management training, endotracheal intubation, evidence-based practice, mannequin simulation, airway occlusion

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review